Dual LED Displays for Simultaneous Indication of Temperature and Setpoint
Status Indicators for Outputs and Control Modes
Thermocouple or RTD Inputs
Optional Dual Alarm Inputs
Optional Linear DC Output, Control or Retransmission (0 to 10 V, 0/4 to 20 mA)
Manual/Automatic Control Modes
Setpoint Ramping For Process Startup
Sensor Error Compensation (Offset) and Break Detection
Heating and Optional Cooling Outputs
Parameter Security Via Programmable Lockouts
Field-Replaceable Output Board
Optional RS485 Serial Communications
产品描述
The CN63100 series has been discontinued. Please see the CND3 Series as a possible alternative or upgrade.
The CN63100 Series Controller accepts signals from a
variety of temperature sensors (thermocouple or
RTD), precisely displays the process temperature, and
provides an accurate output control signal (time
proportional or linear DC) to maintain the process at
the desired temperature. The controller
comprehensive yet simple programming allows it to
meet a wide variety of application requirements. The
controller operates in the PID control mode for both
heating and cooling, with on-demand auto-tune, which
will establish the tuning constants. The PID tuning
constants may be fine-tuned by the operator at any
time and then locked-out from further modification.
The controller employs a unique overshoot
suppression feature, which allows the quickest
response without excessive overshoot. The unit can
be transferred to operate in the manual mode,
providing the operator with direct control of the output.
The controller may also be programmed to operate in
the “ON/OFF” control mode with adjustable hysteresis.
A second setpoint is available on select models to
allow quick selection of a different setpoint setting.
Dual 4-digit displays allow viewing of the process
temperature and setpoint simultaneously. Front panel
indicators inform the operator of the controller and
output status. On many models the main control
output and the alarm outputs are field replaceable.
Optional alarm(s) can be configured to activate
according to a variety of actions (absolute high or low,
deviation high or low, band in or out, with
adjustable hysteresis. A standby feature
suppresses the alarm during power-up
until the temperature stabilizes outside
the alarm region. The second alarm
can be configured as a secondary PID
output (heat/cool applications).
† 所有金额以RMB显示 注: Comes with complete operator’s manual. For “-C4” RS485 option, software is a free download from omega.com.