One "D" 1.5V Alkaline Battery (Included) for Up to 3½ Years of Service
User-Friendly Front Panel Programming
NEMA 4X (IP66) Enclosure
Meter, Remote, or Swivel Mount Configurations
Loop Powered 4 to 20 mA signal (-LP models)
产品描述
The FTB-1400 series has been discontinued. Please see the DPF140 Series as a possible alternative or contact our Flow Engineering department.
The FTB-1400-D display is a
technologically advanced flow
monitor designed to be
comprehensive, user-friendly,
flexible and cost efficient. This
microprocessor-based display can
easily be configured in the field. The
user may choose between the
standard model which is programmed
in seven simple steps and the
advanced model which provides
additional programming options.
The FTB-1400-D display is offered in
three mounting configurations: meter,
remote and swivel display allowing
for flexible installation. The display,
when paired with a rugged, reliable
OMEGA turbine flowmeter, will
provide dependable and accurate
flow information for many years to
come. The display may also be used
with almost any flow sensor that
outputs a low-amplitude AC signal.
The FTB-1400-D flow monitor
accepts a low-level frequency input,
such as the input from a OMEGA
turbine meter, to calculate flow rate
and total. These calculations are
then displayed in user selected unit
of measurement. They can be
easily configured in the field.
The FTB-1400-D is battery-powered
and utilizes one "D" size, 1.5V
alkaline battery (included) that
provides up to 31.2 years of service.
The displays are equipped with a
large 8 digit by 3.4" numerical LCD
making extended range viewing
practical. The second 8 character
by 3.8" alphanumeric display provides
for selectable units viewing in run
mode and prompts variables in
programming mode. Additionally,
the user can choose between
displaying rate, total or alternating
between both rate and total.
SPECIFICATIONS
LCD Display: Rate and total, fixed or toggle modes of operation 8 digit, 18 mm (0.7") numeric (top line) 8 character, 9 mm (0.35") alphanumeric (bottom line); resettable Power: 1 "D" size 1.5 Vdc alkaline battery (included) less than 1 milliwatt (~3.5 years on 1 "D" battery) Pulse Output Signal: One pulse for each increment of the least significant digit of totalizer. Pulse type opto-isolated open collector transistor Max Voltage: 30 Vdc Pulse Width (ON State): 20 ms/max pulse rate 20 Hz Current (ON State): 0.9V drop at 5.0 mA or 0.7V drop at 0.1 mA Inputs: Magnetic pickup Frequency Range: 1 to 3500 Hz Trigger Sensitivity: 30 mV p-p over voltage protected 30 Vdc Frequency Measurement Accuracy: ±0.1% Operating Temperature: -30 to 70°C (-22 to 158°F) Humidity: 0 to 90% non-condensing Enclosure Rating: NEMA 4X (IP66) Units of Measure (Rate/Total):GPM/gallons, LPM/liters, M3PD/cubic meters, BPD/barrels, M3PH/cubic meters Additional Specifications (-A) Model Thirteen Selectable Units of Measure: Gallons, oil barrels, liters,cubic meters, Mgal, MCF, MMCF, cubic ft, M liters, acre ft, liquid barrels, lbs, or kgs Three Time Units for Rate Measurement: Day, hour, minute, or second ten point linearization programming Meter Mount: Monitor is assembled to the flowmeter, creating a compact flow measurement system
† 所有金额以RMB显示 注: Comes complete with "D" 1.5V alkaline battery and operator’s manual.
Cable is required with RD (remote mount) versions. Cable sold separately.