The HHAQ-110 simultaneously
detects Methane (CH4), Carbon
Monoxide (CO), Oxygen (O2) and Hydrogen
Sulfide (H2S) making it the ideal device
for detecting gas leaks in mines,
chemical plants, refineries and
construction tunnels.
The HHAQ-110 displays the
current level of each gas as well
as the STEL (short term exposure
limit) and TWA (time weighted
average). Concentration alarms
are programmable in three modes
(audible, visual and vibrating). The
catalytic/electrochemical sensor
uses natural diffusion sampling
(typical sensor life 2 years).
The HHAQ-110 is powered by a
rechargeable lithium-ion battery
and includes the charger.
Specifications Measurement Ranges: CH4: 0 to 100% LEL (Lower Explosive Limit) CO: 0 to 1000 ppm O2: 0 to 30% by volume H2S: 0 to 100 ppm Measurement Accuracy: ±2% of
full-scale value Response Time: < 30 seconds to 90%
of final value Alert Levels: 200 ppm STEL +
35 ppm TWA for CO, 15 ppm STEL +
10 ppm TWA for H2S High, Low Alarm Ranges: CH4: 25 to 80% LEL with 50% LEL default, 10 to 25% LEL with 20% LEL default CO: 100 to 500 ppm with 200 ppm default, 25 to 100 ppm with 35 ppm default O2: 22.5 to 24% by volume with 23.5% default, 16 to 19.5% by volume with 23.5% default H2S: 15 to 30 ppm with 15 ppm default, 5 to 15 ppm with 10 ppm defaults Sensor Type: Catalytic (CH4), electrochemical (CO, O2, H2S) LCD Size: 42 mm (1 5/8") diagonal
Operating Life with Fully Charged Battery: 8 hours under
non-alarm conditions Operating Temperature: -20 to 50°C
(4 to 122°F) @ 5 to 95% RH, non-condensing Dimensions: 116 L x 66 W x 31 mm D
(4.6 x 2.6 x 1.2") Weight (with Battery): 200 g (7 oz)
† 所有金额以RMB显示 注: Comes complete with HHAQ-110 meter with built-in Li-ion battery, USB/AC charger,
molded case, universal heavy-duty D-Ring alligator clip, belt clip and operator’s manual.