The OMEGA™ MDS8PT is a 1/8 DIN size (96 x 48 mm) digital
panel meter in a benchtop plastic enclosure featuring the Pt Series color-changing display.
The Pt Series meters feature
4 or 6 digit LED displays that can be
programmed to change color
between GREEN , AMBER, and
RED at any set-point or alarm
point. Other options include
isolated programmable analog
output, serial communications,
Modbus® and Ethernet.
The universal temperature and
process instrument handles 10
common types of thermocouples,
thermistors, multiple RTD’s, and
several process (DC) voltage and
current ranges.
Specifications Single-Channel
Universal Inputs
Accuracy: See table for details Resolution: 1°/0.1°; 10 µV process Temperature Stability: RTD: 0.04°C/°C Thermocouple @ 25°C (77°F):
0.05°C/°C (cold junction compensation) Process: 50 ppm/°C CMRR: 120 dB A/D Conversion: 24-bit sigma delta Digital Filter: Programmable Display: 4- or 6-digit, 9-segment LED,
21 mm (0.83") GREEN, AMBER, and
RED programmable colors for process
variable, set point and temperature units Input Types: Thermocouple, RTD,
thermistor, analog voltage, analog current Thermocouple Type (ITS 90):
J, K, T, E, R, S, B, C, N, L RTD Input (ITS 90): 100/500/1000Ω
Pt sensor, 2-, 3- or 4-wire; 0.00385 or
0.00392 curve Thermistor Input: 2252 Ω, 5K Ω, 10K Ω Voltage Input: -100 to 100 mV, -1 to
1 V, -10 to 10 Vdc Current Input: 4 to 20 mA, 0 to 24
mA scalable Configuration: Differential Polarity: Bipolar Step Response: 0.7 s for 99.9% Decimal Selection: None, 0.1 for
temperature; none, 0.1, 0.01 or
0.001 for process Set-Point Adjustment: -9999 to
9999 counts Span Adjustment: 0.001 to 9999
counts Offset Adjustment: -9999 to +9999 Network and
Communications
Ethernet: Standards Compliance
IEEE 802.3 10/100 Supported Protocols: TCP/IP, ARP RS232/RS485: Selectable from
menu; both ASCII and
Modbus protocol selectable
from menu; programmable 1200 to
115.2 Kb; complete programmable
setup capability; program to transmit
current display, alarm status, min/
max, actual measured input value
and status Connection: USB connector on
front panel; optional alarm 1 and 2
(programmable) Optional Alarm 1 and 2
(Programmable)
Type: Form “C” SPDT relays
Operation: High/low, above/below,
limited output to 30 Vrms, 60 Vdc max,
band, latch/unlatch, normally open/
normally closed and process/deviation;
front panel configurations Optional Analog Output
(Programmable):
Isolated, retransmission 0 to 10 Vdc
or 0 to 20 mA, 500 Ω max (output 1 only).
Accuracy is ± 1% of FS when following
conditions are satisfied.
1) Input is not scaled below 1%
of input FS
2) Analog output is not scaled below
3% of output FS General
Power: 90 to 240 Vac, 50 to 60 Hz Note: Power cords for 120 Vac operation are
available. See “Accessories.”
† 所有金额以RMB显示 注: Comes with quick start manual.
Please select the power cord from the accessories list.