omega-qr-code 微 信 公 众 号
咨询热线 400-820-0559

差分pH或ORP探头

PHETX-600 Series

Differential pH or ORP Probes | PHETX-600 Series

Differential pH or ORP Probes

查看下面所有型号

1年保修
  • Integral 2-Wire 4 to 20 mA Transmitter
  • Accurate Differential Measurement
  • Eliminates Ground Loop Interference
  • Built-In Pre-Amp Supports Up to 914 m (3000') Sensor-to-Analyzer Distance
  • 4.6 m (15') Standard Cable Length
  • Automatic Temperature Compensation on pH Versions
工业pH仪表和电极 - 查看相关产品

产品描述

OMEGA™ pH and ORP differential probes stay in service and provide accurate measurements under conditions that often render conventional pH probes inoperable. These probes, come with an integral encapsulated 4 to 20 mA 2-wire transmitter to feed directly to a PLC or a DCS.
The PHETX-600 and ORETX-600 probes employ a differential measurement technique. Unlike conventional combination probes, the differential probe has two high impedance measurement circuits containing a common metallic return electrode. One circuit includes the process measurement electrode which generates a potential E1 proportional to the process pH. The second circuit includes an internal measurement electrode immersed in a stable buffer solution which generates a standard reference potential, E2. Both circuit share a common potential E3 developed at the return electrode. The two circuits are fed into amplifiers which provide an output representing the differential between them: (E1 - E 3)– (E2 - E3). The common potential E3 is cancelled out electronically, greatly reducing inaccuracies caused by ground loops which may exist between process and instrument grounds. Ground loop current will flow through the low impedance path of the return electrode, affecting the potential E3, but not the differential measurement.
The differential probe maintains its accuracy and stability in aggressive process applications long after a combination-style probes performance begins to deteriorate. Maintenance costs are reduced and the life of the probe is increased. The internal reference electrode is electrically connected to the process solution by means of a field-replaceable double junction salt bridge which greatly reduces the possibility of contamination of the buffer solution in the reference circuit. Although seldom required, the reference solution may be easily replaced by removing the screw-out salt bridge. A salt bridge and buffers are available for this purpose.
Another advantage of the PHETX/ ORETX-600 series are the semi-flush face which is easily cleaned and avoids solution materials gathering on protrusions found in other probes. The domed glass electrode, the protective metal electrode and the temperature sensor protrude only about 18" while the salt bridge is flush. A flat-face version of the pH probe is also available. The PHETX/ORETX-600 series is available in: 1½ NPT threaded body style (-600), “easy-in, easy-out” variable insertion depth version with 1¼ NPT compression fitting (-610), or the hot tap version (-620).

SPECIFICATIONS
Measuring Range:
    pH: 0 to 14 pH (consult factory for applications below 2 or above 12)
    ORP: -500 to 500 mV or 0 mV to 1000 mV, field selectable
Flow Rate: 10 ft/sec max (3 meters/sec) flow should be as low as possible in low conductivity water and in solutions with high suspended solids
Wetted Materials: CPVC, kynar, glass, titanium palladium alloy and EPDM (platinum for ORP probe); opt FKM and ceramic
Transmission Distance: Dependant upon transmission distance and supply voltage 1
Sensitivity:
    pH: 0.001 pH
    ORP: 0.1 mV
Stability
    pH: 0.03 pH per day, non-cumulative
    ORP: 2 mV per day, non-cumulative
Temperature Compensation (Automatic): -5 to 95°C (23 to 203°F)
Pressure Limit: 100 psig at 65°C (149°F) max
Temperature Limits (CPVC): -5 to 95°C (23 to 203°F) the temperature limit of probes in flow through applications is limited by pressure and by the pipe fitting material.
Probe Cable: 4.6 m (15') long
订购 所有价格均为人民币税前价格,不包括13%增值税和运费!(指定型号)
网上下单立享5%折扣!

其他客户同时购买: 这个图标可以点击扩大,跳出的清单包括了其他客户在购买此产品时同时购买的其它产品。

产品编号产品描述
数量
产品描述
Quick Ship
  
PHETX-600
咨询  
货期: 
 
 
1 1/2 NPT differential pH electrode with 4 to 20 mA outout
Quick Ship
  
ORETX-600
咨询  
货期: 
 
 
1 1/2 NPT differential ORP electrode with 4 to 20 mA outout
Quick Ship
  
PHETX-610
咨询  
货期: 
 
 
Compression fitting pH electrode with 4 to 20 mA output for 7/8 to 5" variable insertion
Quick Ship
  
ORETX-610
咨询  
货期: 
 
 
Compression fitting ORP electrode with 4 to 20 mA output for 7/8 to 5" variable insertion
Quick Ship
  
PHETX-620
咨询  
货期: 
 
 
Hot tap pH electrode with 4 to 20 mA output for 7/8 to 5" variable insertion
Quick Ship
  
ORETX-620
咨询  
货期: 
 
 
Hot tap ORP electrode with 4 to 20 mA output for 7/8 to 5" variable insertion
Accessories
Quick Ship
  
PHE-600-SB
¥1,745.53
货期: 6 周
 
Replacement salt bridge kit for 600 Series
Quick Ship
  
PHE-612-SB
¥1,745.53
货期: 6 周
 
Replacement salt bridge kit for 610 Series
Quick Ship
  
PHE-600-EP
¥1,745.53
货期: 6 周
 
Electrode protector for 600 Series
Quick Ship
  
PHE-610-EP
咨询  
货期: 
 
 
Electrode protector for 610 Series
Quick Ship
  
PHE-620-BVA
咨询  
货期: 
 
 
PVC hot tap ball valve assembly for 620 Series
所有金额以RMB显示
注: Comes complete with electrode, salt bridge and operator’s manual.