Dual Mineral Insulated Thermocouple Cable (MI Cable), Metal Sheath |
304-(*) -DUAL and INC-(*)-DUAL Series |
|
|
|
|
Dual Mineral Insulated Thermocouple Cable
|
Click for larger image. |
|
|
¥
73.00
304-K-MO-250-DUAL
|
|
Mineral Insulated Cable, 4 Wire MIC with Mgo
|
|
4 Wire Dual Thermocouple MI Cable
|
|
High Temperature Applications
|
|
Weldable and Bendable
|
|
Protective Hard Outer Sheath
|
|
304, 310, 316, 321 Stainless Steel Sheath Material or Inconel 600 Sheath Material
|
|
Internal Conductors Thermocouple J, K, T, E, N
|
View related products - Wire: Thermocouple, RTD, Thermistor and Hook-Up
|
| |
|
|
|
OMEGACLAD™ dual pair mineral insulated M.I. cable can be made into a
single probe that enables
transmission of a “split
signal”. MgO style cable can be used to make nonexpendable thermocouple test sensors. This double signal 4 wire MIC
can be attached to a
controller and chart recorder
at the same time to both monitor
and control the same
temperature location.
4 Wire Dual, 2 pair of TC conductors available in Standard Inch and Metric OD sizes:
0.375" (9.5 mm)
0.312" (7.9 mm) and 8.0mm
0.250" (6.4 mm) and 6.0mm
0.188" (4.8 mm) and 5.5mm or 4.5mm
0.125" (3.2 mm) and 3.0mm
0.062" (1.6 mm) 4 wire dual MIC with MgO
Technical Notes:
OMEGACLAD™ wire can be
made into a grounded junction
probe and inserted into a pipe
with compression fitting.
Insulation Compacted
magnesium oxide is hygroscopic
(absorbs moisture)
Model No. |
Wire Calibration |
Sheath Material |
Sheath Diameter (in.) |
Wall Thickness (in.) |
Resistance at 60°F Ohms/ Dbl. ft. |
Dia. of Wires (in.) |
AWG Gage |
304-J-MO-062-DUAL 304-J-MO-125-DUAL 304-J-MO-188-DUAL 304-J-MO-250-DUAL | Iron- Constantan J | 304 Stainless Steel | 0.062 0.125 0.188 0.250 | 0.010 0.018 0.025 0.036 | 3.6 0.88 0.36 0.22 | 0.010 0.020 0.032 0.040 | 30 24 20 18 |
INC-J-MO-062-DUAL INC-J-MO-125-DUAL INC-J-MO-188-DUAL INC-J-MO-250-DUAL | Iron- Constantan J | Inconel 600 | 0.062 0.125 0.188 0.250 | 0.010 0.018 0.025 0.036 | 3.6 0.88 0.36 0.22 | 0.010 0.020 0.032 0.040 | 30 24 20 18 |
304-K-MO-062-DUAL 304-K-MO-125-DUAL 304-K-MO-188-DUAL 304-K-MO-250-DUAL | CHR- AL K | 304 Stainless Steel | 0.062 0.125 0.188 0.250 | 0.010 0.018 0.025 0.036 | 6.0 1.5 0.59 0.37 | 0.010 0.020 0.032 0.040 | 30 24 20 18 |
INC-K-MO-062-DUAL INC-K-MO-125-DUAL INC-K-MO-188-DUAL INC-K-MO-250-DUAL | CHR- AL K | Inconel 600 | 0.062 0.125 0.188 0.250 | 0.010 0.018 0.025 0.036 | 6.0 1.5 0.59 0.37 | 0.010 0.020 0.032 0.040 | 30 24 20 18 |
304-T-MO-062-DUAL 304-T-MO-125-DUAL 304-T-MO-188-DUAL 304-T-MO-250-DUAL | Copper- Constantan T | 304 Stainless Steel | 0.062 0.125 0.188 0.250 | 0.010 0.018 0.025 0.036 | 3.0 0.75 0.298 0.19 | 0.010 0.020 0.032 0.040 | 30 24 20 18 |
INC-T-MO-062-DUAL INC-T-MO-125-DUAL INC-T-MO-188-DUAL INC-T-MO-250-DUAL | Copper- Constantan T | Inconel 600 | 0.062 0.125 0.188 0.250 | 0.010 0.018 0.025 0.036 | 3.04 0.75 0.19 0.19 | 0.010 0.020 0.032 0.040 | 30 24 20 18 |
304-E-MO-062-DUAL 304-E-MO-125-DUAL 304-E-MO-188-DUAL 304-E-MO-250-DUAL | CHR- Constantan E | 304 Stainless Steel | 0.062 0.125 0.188 0.250 | 0.010 0.018 0.025 0.036 | 7.17 1.78 0.71 0.45 | 0.010 0.020 0.032 0.040 | 30 24 20 18 |
INC-E-MO-062-DUAL INC-E-MO-125-DUAL INC-E-MO-188-DUAL INC-E-MO-250-DUAL | CHR- Constantan E | Inconel 600 | 0.062 0.125 0.188 0.250 | 0.010 0.018 0.025 0.036 | 7.17 1.78 0.71 0.45 | 0.010 0.020 0.032 0.040 | 30 24 20 18 |
|
|
|
|
|
|
† Price are shown in RMB.
Note: •Technical Notes: OMEGACLAD™ wire can be made into a grounded junction probe and inserted into a pipe with compression fitting. Insulation Compacted magnesium oxide is hygroscopic (absorbs moisture) •For 310, 316 or 321 stainless steel sheath, change “304” in the Model Number to “310”, “316” or “321”(non-standard partnumber); no additional charge. •For SUPER OMEGACLAD™ XL, change “304” in the Model Number to “XL” (non-standard partnumber, price given on request). •For Special Limits of Error, add suffix “-SLE” to Model Number; add 20% to price.
|
|
|
|
|
|
|
|
|
Part Number Builder |
|
|
|
|
|
|
Option Descriptions
|
(1)
|
Sheath Material
|
|
Select 304 for 304 Stainless Steel INC for Inconel 600
(2)
|
Thermocouple Type
|
|
Select J for J Thermocouple K for K Thermocouple T for T Thermocouple E for E Thermocouple
(3)
|
Sheath Diameter
|
|
Select 062 for 0.062 in. 125 for 0.125 in. 188 for 0.188 in. 250 for 0.250 in.
(4)
|
Special Limits of Error
|
|
Select Nothing(leave field blank) for None -SLE for Special Limits of Error
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| | |
|
|
|
|
|
| |
Related Links -
Related Products
|
|
|
Related Products
|
|
|
316-RTD-4W-MO-250:
|
RTD MI Cable OMEGACLAD™ RTD Mineral Insulated Cable, 2, 3, or 4 Conductor MIC with MgO
|
|
|
|
|
DTC-(*):
|
4-Prong Dual Circuit Standard Connectors
|
|
|
|
|
|
|
|
|
Keywords:M.I.Cable
Thermocouple Wire
Dual OMEGACLAD,
Mineral Insulated Cable,
Magnesium Oxide Insulation,
MgO insulated thermocouple wire,
instrument cables,
mineral insulation,
mi cable pricing,
mi cable manufacturer,
metal sheath cable
, thermocouple chart thermocouple voltage temperature
|
Back to top
|