Recommended Excitation: 28 VDC ±4 VDC Rated Output (RO): 5 VDC ±0.25%
(±10% Adjustable) Short Circuit Protected Zero Balance (% RO): ±10% Adjustable (Min.) Temperature Effect on Zero Balance
(% RO): 0.0015/°F (0.0027%/°C) Max. Temperature Effect on Output
(% Reading): 0.0020/°F (0.0036/°C) Max. Compensated Temperature Range:
-25 to 150°F (-32 to 66°C) Min.
Safe Over Temperature Range:
-65 to 250°F (-54 to 121°C) Min. Overpressure Range (%RO):
5 psi: 300% RO Min.
10-5000 PSI: 150% RO Min. Ultimate Overpressure Range (%RO)
5-200 psi: 800% RO Min.
350-2000 psi: 300% RO Min.
(Diaphragm shall not rupture) Combined Effects Non-Linearity, Hysteresis
and Repeatability: 0.25% RO (Max.) Vibration Limit (5-2000 Hz): 0.04% RO/G (Max.) Thermal Zero Stability (%RO): 0.4% RO (Max.) Thermal Sensitivity Stability (%RO):
0.3% RO (Max.)
Part Number
Range
Units
Accuracy
5SE01313-1
0-5
PSIG
0.25%
5SE01313-2
0-10
PSIG
0.25%
5SE01313-3
0-20
PSIG
0.25%
5SE01313-4
0-50
PSIG
0.25%
5SE01313-5
0-100
PSIG
0.25%
5SE01313-6
0-150
PSIG
0.25%
5SE01313-7
0-200
PSIG
0.25%
5SE01313-8
0-500
PSIG
0.25%
5SE01313-9
0-1000
PSIG
0.25%
5SE01313-10
0-1500
PSIG
0.25%
5SE01313-11
0-2000
PSIG
0.25%
5SE01313-12
0-5000
PSIG
0.25%
5SE01313-13
0-50
IN.HgG
0.25%
5SE01313-14
0-100
IN.HgG
0.25%
5SE01313-15
0-200
IN.HgG
0.25%
5SE01313-16
0-500
IN.HgG
0.25%
5SE01313-17
0-1000
IN.HgG
0.25%
5SE01313-18
0-20
PSIA
0.25%
5SE01313-19
0-50
IN.H2OG
0.25%
5SE01313-20
0-300
PSIG
0.25%
5SE01313-21
0-600
IN.HgA
0.25%
5SE01313-22
0-50
IN.HgA
0.25%
5SE01313-23
0-100
IN.HgA
0.25%
5SE01313-24
0-400
IN.HgA
0.25%
5SE01313-25
0-300
PSIA
0.25%
Please note these transducers are specialty items. Pricing is available by quotation only. Please contact our Pressure Engineering
department to receive a quote.