1/16 Din Universal Temperature & Process Controllers with 8 Segment Ramp/Soak Capability |
CN8201 Series |
|
 |
|
|
 |
The CN8200 temperature/process controller is extremely versatile and user-friendly. The operator needs to review only those parameters relevant to the particular application during setup. A dual digital display offers optimum process information at a glance. Individual LED's identify the status of outputs, alarms, digital communications, and special options. The CN8200 features a NEMA-4X front panel and a universal power supply that accepts 100 to 250 Vac and 120 to 250 Vdc. A 24 Vac/24 Vdc power supply option is also available. Control algorithms available are P, PI, PD, PID, or ON/OFF. The autotune feature automatically sets proportional band, derivative, and integral before the process reaches setpoint. These parameters provide quick stabilization of processes with minimum overshoot, hunting, or cycling. Eight-level ramp/soak control consisting of 8 ramps and 8 soaks is standard, and includes a decimal display on thermocouple ranges, digital display and signal filtering, and a percentage of power limit setting. The dual control outputs can be configured for a variety of control and alarm applications, and two dedicated alarm outputs are also available. The CN8200 offers a wide range of options, including RS-232 and RS-485 digital communications, five remote analog setpoint ranges, three contact/digital input modes, four transducer excitation voltages, and four auxiliary output ranges.
Specifications
Performance
Accuracy: ±0.2% of full scale, ±1 digit
Setpoint Resolution: 1 count/0.1 count
Repeatability: ±1 count
Temperature Stability: 5 µV/°C (maximum)
TC Cold-Junction Tracking: 0.05°C/°C ambient
Common Mode Rejection: 100 dB
Series Mode Rejection: >70 dB
Process Sampling: 10 Hz (100 ms)
Inputs
Input Type: See Input Table
Digital Input: For remote setpoint, remote standby or ramp/soak run and hold
Thermocouple Lead Resistance: 100 ohms max for rated accuracy
Decimal Position: Selectable
Outputs
Output #1: Reverse or directacting, configured from menu
Output #2: Reverse or directacting, configured from menu
Mechanical Relay: Rated 5 A @120 Vac, 3 A @ 240 Vac, normally open (N.O.), normally closed (N.C.), (output 1); Rated 5 A @120 Vac, 3 A @ 240 Vac, N.O. (output 2)
Current: 4 to 20 mA, 500 ohm max (suffix F1, F2); 4 to 20 mA, 1000 ohm max (suffix FH1, FH2)
Voltage: 20 Vdc pulse
Solid State Relay: SSR, 120/240 Vac, zero voltage switched, rated 1 A continuous, 10 A surge @ 25°C
Alarms: Mechanical relay rated 5 A @ 120 Vac, 3 A @ 240 Vac, N.O.; Optically isolated SSR rated 1 A, 120/240 Vac @ 25°C; dc alarms, 24 Vdc
Transducer Power Supply: 5, 10, 12, 15 Vdc ±10%
Control Characteristics
Setpoint Limits: Limited to configured range for thermocouple and RTD; limited to scaled range
Alarms: Adjustable for high/low; selectable process or deviation
Rate (Derivative): 0 to 2400 seconds
Reset (Integral): 0 to 9600 seconds
Cycle Time: 0.2 to 120 seconds
Proportional Band: 1 to span of sensor
Deadband: negative span to positive span of sensor
Hysteresis: 1 to span of sensor Autotune Damping: Adjustable (low, normal, or high)
Ramp to Setpoint: 1 to 9999 minutes
Autotune: Operator-initiated from front panel
Manual Control: Operator-initiated from front panel General
Power: 100 to 250 V, 50/60 Hz (single-phase), 120 to 250 Vdc, 24 Vac/24 Vdc optional
Display: Dual LED, 4-digit, orange: process display, green: menu/ parameter display; 9.2 mm (0.36")
Power Consumption: Less than 6 VA (instrument) @ 120 Vac
Weight: 226 g (8 oz)
Panel Cutout: 45 mm (1.771") square
Dimensions: 53.3 H x 53.3 W x 8.21 mm D (2.1 x 2.1 x 0.72") bezel
Depth Behind Panel: 100 mm (3.937")
Front Panel Rating: NEMA-4X
Operating Ambient Range: 0 to 55°C (32 to 131°F)
Humidity: 90% RH max, non-condensing
Memory Protection: Solid-state non-volatile memory
Connections: Screw terminals
Contacts: Twin bifurcated
Ramp/Soak Programming
Intervals: 8
Loops: 0 to 99
Ramp Time: 0 to 9999 minutes
Soak Time: 0 to 9999 minutes
Events/Alarms: 1 to 8
Ramp Setpoint: 1 to 9999 minutes
CN8-SW (Optional Software)
Minimum Hardware and Software Requirements: IBM PC or 100% compatible, Windows 95/98/NT; RS-485 interface or RS-232 to RS-485 converter
Software Compatibility: CN8200 Series controllers
Software Capability: Supports up to 254 CN8200 Series controllers.
Input and Range Table for Universal Input Controller
Input Type | Range |
J Iron Constantan | -200 to 760°C (-328 to 1400°F) |
K CHROMEGA™-ALOMEGA™ | -270 to 1354°C (-454 to 2469°F) |
T Copper-Constantan | -270 to 400°C (-454 to 752°F) |
N OMEGALLOY™ | -268 to 1300°C (-450 to 2372°F) |
R Pt/13%Rh - Pt | -50 to 1768°C (-58 to 3214°F) |
S Pt/10%Rh - Pt | -50 to 1768°C (-58 to 3214°F) |
B Pt/30%Rh - Pt/6%Rh | 0 to 1820°C (32 to 3308°F) |
C W/5%Re - W/26%Re | 0 to 2315°C (32 to 4199°F) |
E CHROMEGA™-Constantan | -150 to 1000°C (-238 to 1832°F) |
NNM 18% Molybdenem vs Nickel -06% Cobalt | 0 to 1410°C (32 to 2570°F) |
Platinel II | -100 to 1232°C (-148 to 2250°F) |
RTD (3-wire) 100 ohm PT | -200 to 850°C (-328 to 1562°F) |
RTD (3-wire) 100 ohm PT | -199.9 to 375.0°C (-199.9 to 707.0°F) |
0 to 1 V | Scalable (-1999 to 9999) Selectable |
1 to 5 V | Scalable (-1999 to 9999) Selectable |
0 to 5 V | Scalable (-1999 to 9999) Selectable |
0 to 10 V | Scalable (-1999 to 9999) Selectable |
10 to 50 mV | Scalable (-1999 to 9999) Selectable |
0 to 50 mV | Scalable (-1999 to 9999) Selectable |
0 to 10 mV | Scalable (-1999 to 9999) Selectable |
0 to 100 mV | Scalable (-1999 to 9999) Selectable |
4 to 20 mA | Scalable (-1999 to 9999) Selectable |
0 to 20 mA | Scalable (-1999 to 9999) Selectable |
Output Options–No Additional Cost
Option Type | First Output-Heat or Cool (Reverse or Direct) Order Suffix | Second Output- Heat or Cool (Reverse or Direct) Order Suffix |
Relay | -R1 | -R2 |
dc Pulse | -DC1 | -DC2 |
1A SSR | -T1 | -T2 |
4 to 20 mA (500 ohm max) | -F1 | -F2 |
4 to 20 mA (800 ohm max) | -FH1 | -FH2 |
|
|
|
 |
|
 |
† Price are shown in RMB.
Ordering Example: (1) CN8202-R1-R2-LV-AL3 1/16 DIN dual mechanical relay outputs, ramp/soak process controller, low voltage power, with DC pulse alarms, $289 + 40 + 40 = $369, ¥4,915.00
|
|
 |
|
|
|
|
|
|
Part Number Builder |
|
|
|
|
|
|
Option Descriptions
|
(1)
|
Number of Outputs
|
|
Select 1 for Single Output 2 for Dual Output
(2)
|
First Output
|
|
Select R1 for Relay DC1 for dc Pulse T1 for 1A SSR F1 for 4-20 mA (500 ohm max.) FH1 for 4-20 mA (1000 ohm max.)
(3)
|
Second Output
|
|
Select Nothing(leave field blank) for No second output -R2 for Relay -DC2 for dc Pulse -T2 for 1A SSR -F2 for 4-20 mA (500 ohm max.) -FH2 for 4-20 mA (1000 ohm max.)
(4)
|
Low Voltage Power Input Option to operate unit
|
|
Select Nothing(leave field blank) for standard 100 to 250 Vac input power -LV for 24 Vac/dc input power option
(5)
|
Additional Options
|
|
Select Nothing(leave field blank) for No additional options -AL1 for Single alarm mechanical relay -AL2 for Dual alarms ac SSR -AL3 for Dual alarms dc level (24 Vdc) -C2 for RS-232 communications -C4 for RS-485 communications -C4-DIC for RS-485 with digital input- switch closed -C4-DIO for RS-485 with digital input- switch open -C4-DIV for RS-485 with digital input 0 or 5V -C4-MOD for RS-485 with modbus protocol -C4-MOD-DIC for RS-485 with modbus protocol with digital input switch closed -C4-MOD-DIO for RS-485 with modbus protocol with digital input switch open -C4-MOD-DIV for RS-485 with modbus protocol with digital input 0 or 5V -PVSV2 for Process output PV or SV 0 to 5 Vdc -RSP1 for Remote setpoint switch closed with 1 alarm -RSP2 for Remote setpoint switch open with 1 alarm -RSP3 for 0 or 5 Vdc remote setpoint with 1 alarm -XP1 for Transducer power supply 15 Vdc -XP2 for Transducer power supply 12 Vdc -XP3 for Transducer power supply 10 Vdc -XP4 for Transducer power supply 5 Vdc
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| | | |
|
|
|
|
 |
|  |
Related Links -
Manual, Related Products
|
|
|
Product Manual
|
Download
CN8201 - 1/16 DIN Temperature/Process Controllers
|
Download
CN8200 Series - CN8200 series Communications & Options Guide
|
Download
CN8200, CN8240, CN8260 - Modbus Protocol
|
Download
CN8202 - 1/16 DIN Temperature/Process Controllers
|
Download
CN8-SW - Software for CN8200, CN8400, CN8500 Series
|
Download
CN8-SW - Communications Software for CN8500 & CN8200 Series Controllers
|
Related Products
|
|
|
|
|
|
|