Fully Isolated RS-232/RS-485 Converters |
DCP-485 |
|
|
|
|
Fully Isolated RS-232/RS-485 Converters
|
Click for larger image. |
|
|
¥
3,250.00
DCP-485-P
|
|
1500 VRMS Isolation with
Optical Couplers and
Power dc-to-dc Converter
(6,000 Vdc, 1 min)
|
|
Industrial Surge
Protection Devices
and 15 KV ESD Protected
RS-232 Inherent
|
|
Four LED Diagnostic
Indicators
|
|
115.2 K BPS (BAUD)
at 0.8 mile (1.3 km),
38.4 K BPS (BAUD)
at 1 mile (1.6 km)
|
|
RTS, DTR, or Auto
RS-485 Transmitter
Control
|
|
Tri-State Outputs for
Multidrop Applications,
up to 32 Devices
|
|
Pluggable Solderless
Screw Terminal Field
Connections
|
|
Easily Mounts on
Standard DIN Rail
|
|
2-Wire or 4-Wire RS-485
|
View related products - Communication Products and Converters
|
| |
|
|
|
The DCP-485 is a compact RS-232-
to-RS-485 converter which features
a complete electrical isolation
barrier and heavy duty electrical
surge protectors. These devices
feature a DIN rail mountable
enclosure, for application to a
junction box, a panel, a relay rack,
the side of your computer, or
anywhere a DIN rail can be
mounted. Isolation is provided by
optical couplers and a transformer-isolated
dc-to-dc converter. The
RS-232 connection is made through
male or female EIA 9-pin D sub
connectors, or a 3-wire RS-232
connection can be made through
convenient pluggable screw
terminals. The RS-485 connections
are made through convenient
pluggable solderless screw terminals.
The DCP-485 series is designed for
full duplex operation over two-wire
pairs. Outputs are tri-state, allowing
multidropping of up to 32 units. Data
rates are up to 115.2 K bits per
second (baud). Four diagnostic LED indicators are provided
for installation guidance
and system troubleshooting. The
RS-232 interface includes Request
To Send (RTS) and Data Terminal
Ready (DTR), either of which can be
used via a DIP switch to enable the
RS-485 transmitter. Alternately, the
DCP-485 offers automatic line
switching: the RS-485 transmitter is
enabled automatically by each
character sent on the RS-232
Transmit Data (TD) line.
Additionally, the RS-485 transmitter
and receiver can be independently
enabled continuously or under
RS-232 control. A convenient null
modem switch is provided for the
data lines. Also, line termination
switches independently connect line
termination and line bias resistors to
the RS-485 lines. The units are
powered from wide-range voltages
of +10 to +30 Vdc through pluggable
solderless screw terminals.
SPECIFICATIONS
Baud Rates (bps): 115.2 K, 57.6 K,
38.4 K, 19.2 K, 9.6 K, 4.8 K, 0-2.4 K
Distance (miles): 0.8, 0.9, 1.0, 2.6,
3.5, 4.0, 7.0
Distance (km): 1.3, 1.5, 1.6, 4.2,
5.6, 6.4, 11.3
Wire Capacitance: Equal to 25 pF
per foot and up to 32 multidrop units
Max Multidrop Units: 32
COMMON MODE ISOLATION
Surge: 6000 Vdc, 1 min
Continuous: 1500 Vrms
Differential Mode Surge Protection: dc input and RS232
inputs and outputs, RS485 inputs and outputs
Modes: Asynchronous 4–wire duplex, 2–wire half duplex, 2–wire simplex
Channel Lines: (1) TD, RD
Control Lines: (1) RTS, DTR
Null Modem Switch: 1 (Reverses RS232 pins 2 and 3)
RS485 Output Drive: 28 mA max/output
RS485 Input Impedance: 12 kΩ min/input
Power: 10 to 30 Vdc @ 150 mA max
TEMPERATURE
Operating Range: 0 to 60°C (32 to 140°F)
Storage Range: 0 to 70°C (32 to 158°F)
Relative Humidity: 0 to 95 %RH non-condensing
Altitude: To 4574 m (15,000')
Dimensions: 109 H x 84 W x 22.5 mm D (4.3 x 3.3 x 0.89")
Weight: 130 g (4.6 oz)
MTBF: (2) >100,000 hrs
|
|
|
|
|
|
† Price are shown in RMB.
Note: DCP-485 comes with a operator’s manual
Ordering Example: (1) DCP-485-P Isolated RS232/RS485 converter with male RS232 9-pin connector, ¥3,250.00
|
|
|
|
|
| |
Related Links -
Related Products
|
|
|
|
|
|
|