1/8 DIN Temperature Panel Meter |
DP6070 Series |
|
|
|
|
|
|
|
|
Modular USB, RS232, RS485 Serial Communication Options and Relays
|
|
J, K, T, E, R, S, B, N, C Thermocouples
|
|
100 or 1000 Ù Platinum, 10 Ù Copper, 120 Ù Nickel RTDs
|
|
1 or 0.1° Resolution
|
|
Automatic Cold Junction Compensation
|
|
NEMA 4X (IP65) Front
|
|
Universal 85 to 265 Vac or 12/24 Vdc Input Power
|
|
Large Dual-Line 6-Character Display, 15 and 12 mm (0.60 and 0.46")
|
|
Sunlight Readable Display Models
|
|
2 or 4 Relays Plus Isolated 4 to 20 mA Output Options
|
|
External 4-Relay and Digital I/O Expansion Modules
|
|
Free Software for Operation, Monitoring and Programming
|
View related products - Temperature & Process Meters, Industrial Timers and Counters
|
| |
|
|
|
The DP6070 temperature
meter boasts specifications and
functionality that clearly makes
it one of the most advanced
temperature meters available.
It’s dual-line 6-character display,
function keys, and optional
expansion modules are only a few
of the special features available.
The DP6070 accepts many
thermocouple types and RTDs and
can be configured to have either
a 1° or 0.1° display resolution
on any type of sensor input. The
lower display makes configuration
simpler. The display itself is quite
configurable. There are many
relay functions for up to 8 relays;
including an Interlock Relay
function. The 4 to 20 mA output
can represent up to 12 different
parameters/variables. This makes
the DP6070 one of the most
versatile meters on the market.
Sunlight readable display models
have an extraordinarily bright
LED display. The upper display
can be programmed to indicate
current temperature, maximum or
minimum temperature, alternating
maximum/minimum temperatures,
one of eight alarm set points, or
Modbus input. The lower display
can also be configured to display
engineering units, set points,
user defined legends, or simply
turned off. Input selection and
configuration are conveniently
set up via rear switches and
front panel programming. Three
levels of password protection
help maintain the reliability of the
programming.
General Specifications
Display: Both displays are 6 digits (-99999 to 999999), red LEDs with leading zero blanking
Upper Display: 15 mm (0.60") high
Lower Display: 12 mm (0.46") high
Display Intensity: 8 intensity levels
Display Update Rate: 5/second (200 ms)
Overrange: Display flashes 999999
Underrange: Display flashes -99999
Display Assignment: The upper and lower displays may be assigned to PV1, PV2, PCT (percent), max/min, alternate max and min, set points, units (lower display only), or Modbus input
Front Panel: NEMA 4X (IP65)
Programming Methods: 4 front panel buttons, digital inputs, PC and software, Modbus registers, or cloning using copy function
Noise Filter: Programmable from 2 to 199 (0 will disable filter)
Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span
Recalibration: Calibrated at the factory. Recalibration is recommended at least every 12 months
Max/Min Display: Max (peak)/min (valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled
Password: 3 programmable passwords restrict modification of programmed settings; Pass 1: Allows use of function keys and digital inputs; Pass 2: Allows use of function keys, digital inputs and editing set/reset points; Pass 3: Restricts all programming, function keys, and digital inputs
Non-Volatile Memory: All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost
Power Options: 85 to 265 Vac 50/60 Hz, 90 to 265 Vdc, 20 W maximum, or jumper selectable 12/24 Vdc ±10%, 15 W max
Fuse (External, Required): UL recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse,br>
Isolated Transmitter Power Supply: 24 Vdc ±5% @ 200 mA maximum (standard), (12/24 Vdc powered models rated @ 100 mA maximum); 5 or 10 Vdc @ 50 mA maximum, selectable with internal jumper J4
Normal Mode Rejection: Greater than 60 dB at 50/60 Hz
Isolation: 4 kV input/output-to-power line; 500V input-to-output or output-to-P+ supply
Overvoltage Category: Installation overvoltage category II, local level with smaller transient overvoltages than installation overvoltage category III
Operating Temperature Range: -40 to 65°C (-40 to 149°F)
Storage Temperature Range: -40 to 85°C (-40 to 185°F)
Relative Humidity: 0 to 90% non-condensing
Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adaptors
Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting: 1/8 DIN panel cutout required: 92 x 45 mm (3.622 x 1.772"); two panel mounting bracket assemblies are provided
Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
Overall Dimensions: 119 W x 62 H x 143 mm D (4.68 x 2.45 x 5.64")
Weight: 269 g (9.5 oz)
|
|
|
|
|
|
† Price are shown in RMB.
Note: Comes complete with 2 side mounting brackets and operator’s manual.
|
|
|
|
|
|
|
|
|
Part Number Builder |
|
|
|
|
|
|
Option Descriptions
|
(1)
|
Output
|
|
Select 6R0 for Temperature panel meter 6R2 for Temperature panel meter with 2 relays 6R3 for Temperature panel meter with 4 to 20 mA output 6R4 for Temperature panel meter with 4 relays 6R5 for Temperature panel meter with 2 relays and 4 to 20 mA output 6R7 for Temperature panel meter with 4 relays and 4 to 20 mA output 6H0 for Temperature panel meter 6H2 for Temperature panel meter with 2 relays 6H3 for Temperature panel meter with 4 to 20 mA output 7H0 for Temperature panel meter 7H2 for Temperature panel meter with 2 relays 7H3 for Temperature panel meter with 4 to 20 mA output
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
|
|
|
|
|
| |
|
Keywords:1/8 DIN Temperature Panel Meter
|
Back to top
|
|
|