Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation
800-819-0559 (Landline) | 400-619-0559 (Cell)

Transit-Time Ultrasonic Flow Meter  - Discontinued

FDT-30 Series   
1 year warranty CE
 
Transit-Time Ultrasonic Flow Meter
FDT-30 Series:Transit-Time Ultrasonic Flow Meter  - Discontinued
Click for larger image.
   
Compact Enclosure
Large Digital Display
4 to 20 mA, TTL and Turbine Simulated Outputs
Rate and Total Displays
Clean Liquid Compatible
Click to scroll below to order See Specs PDF View a printer friendly page

The FDT-30 series has been discontinued. Please see the FDT-40 as a possible alternative or contact our Flow Engineering department.

The FDT-30 Series provides easy and low cost installation by clamping to the outside of existing piping systems. Non-invasive transit time system allows solids to pass through the pipe with no affect on the meter. Y-strainers or filtering devices are not needed. Greater accuracy can be attained in applications consisting of entrained gases. The FDT-30 Series will automatically correct displayed flow rates and electronic outputs. Direct interface is provided to data collection systems via 4 to 20 mA output and either TTL-pulse or simulated turbine meter outputs that are proportional to fluid flow rate. Designed to replace mechanical flowmeters in applications where liquid conditions tend to damage or impede mechanical flow meter operation. No maintenance is required. The FDT-30 Series can be used on applications such as well water and other liquids with moderate amounts of suspended solids or aeration.

FDT-30 Series is housed in an enclosure suitable for outdoor mounting. Integral mount transducers are available for pipes 50 mm (2") and smaller.

SPECIFICATIONs
Liquid Types: Most clean liquids, or liquids containing moderate amounts of suspended solids
Power: 11.4 to 30 Vdc @ 0.25 A
Velocity: 0.03 to 12.4 MPS (0.1 to 40 FPS)
4 to 20 mA Output (Standard): 12-bit resolution; source power; 5V max insertion loss; 900 Ω max loop impedance; can share ground common with power supply-isolated from piping system
Turbine Frequency Output (TTL Pulse): Switch selectable; non-ground referenced AC, ground referenced squarewave; 100 mV pp min/5 Vdc amplitude; 0 to 1 kHz range; 50% ±10% duty cycle
Display: 2 line x 8 character LCD alternates between rate and total in 10 second intervals
Top Row: 18 mm (0.7"), 7-segment
Bottom Row: 9 mm (0.35"), 14-segment
Rate: 8 digits max
Totalizer: 8 digits max; exponential multipliers from -1 to +6
Units: Feet, gallons, ft³, million-gal, barrels (liquid and oil), acre-feet, lbs, meters, m³, liters, million-liters, kg; rates programmable for per: sec, min, hr, or day
Operating Ambient: -40 to 85°C (-40 to 185°F)
Enclosure: NEMA 3 ABS, PVC and Ultem, brass or SS hardware
Dimensions: 75 W x 150 L x 63 mm D (3 x 6 x 2.5")
Transducer Type: Clamp-on for pipe mount; time of flight ultrasonic
Accuracy: ±1% rdg @ rates > 0.3 MPS (1 FPS); ±0.003 MPS (0.01 FPS) @ rates < 0.3 MPS (1 FPS)
Repeatability: ±0.5% rdg
Response Time: 0.3 to 30 sec, adjustable
Protection: Reverse polarity, surge suppression
Pipe Sizes: 12 to 50 mm (0.5 to 2")
Pipe Materials: Carbon steel, stainless steel, copper and plastic
Order on www.omegaengineering.cn and 5% will be discounted when you checkout.
  To Order (Specify Model Number)
All list prices are pre-VAT rate not including tax and shipping
 
 Part Number   Availability   Price(RMB)   Description    Qty.
 For Carbon Steel/Stainless Steel/ANSI Pipe
 FDT-31    Consult sales   2 to 100 LPM (0.5 to 25 GPM) range, 1/2' ANSI carbon steel/stainless steel pipe  
 FDT-32    Consult sales   4 to 200 LPM (1 to 55 GPM) range, 3/4' ANSI carbon steel/stainless steel pipe  
 FDT-33    Consult sales   8 to 375 LPM (2 to 100 GPM) range, 1' ANSI carbon steel/stainless steel pipe  
 FDT-34    Consult sales   15 to 570 LPM (4 to 150 GPM) range, 1-1/4' ANSI carbon steel/stainless steel pipe  
 FDT-35    Consult sales   18 to 830 LPM (5 to 220 GPM) range, 1-1/2' ANSI carbon steel/stainless steel pipe  
 FDT-36    Consult sales   30 to 1500 LPM (8 to 400 GPM) range, 2' ANSI carbon steel/stainless steel pipe  
 For Copper Pipe
 FDT-31-C    Consult sales   2 to 100 LPM (0.5 to 25 GPM) range, 1/2' copper pipe  
 FDT-32-C    Consult sales   4 to 200 LPM (1 to 55 GPM) range, 3/4' copper pipe  
 FDT-33-C    Consult sales   8 to 375 LPM (2 to 100 GPM) range, 1' copper pipe  
 FDT-34-C    Consult sales   15 to 570 LPM (4 to 150 GPM) range, 1-1/4' copper pipe  
 FDT-35-C    Consult sales   18 to 830 LPM (5 to 220 GPM) range, 1-1/2' copper pipe  
 FDT-36-C    Consult sales   30 to 1500 LPM (8 to 400 GPM) range, 2' copper pipe  
 For Plastic Tubing
 FDT-31-T    Consult sales   2 to 100 LPM (0.5 to 25 GPM) range, 1/2' plastic tubing  
 FDT-32-T    Consult sales   4 to 200 LPM (1 to 55 GPM) range, 3/4' plastic tubing  
 FDT-33-T    Consult sales   8 to 375 LPM (2 to 100 GPM) range, 1' plastic tubing  
 FDT-34-T    Consult sales   15 to 570 LPM (4 to 150 GPM) range, 1-1/4' plastic tubing  
 FDT-35-T    Consult sales   18 to 830 LPM (5 to 220 GPM) range, 1-1/2' plastic tubing  
 FDT-36-T    Consult sales   30 to 1500 LPM (8 to 400 GPM) range, 2' plastic tubing  
 Accessories
 FDT-30-PC CABLE 6 Weeks   ¥2,570.00    PC Communications Cable (recommended for first time buyers allows programming of the FDT-30 series with a PC)  
 FDT-30-CABLE CLAMP 2 Weeks   ¥242.00    Water tight cable clamp  
 FD-GREASE 2 Weeks   ¥279.00    Acoustic couplant for sensor mounting, max temperature 65°C (150°F), 6 g (.2 oz) pillow pack  
 FDT-GREASE In Stock   ¥710.00    Replacement acoustic couplant for sensor mounting, max temperature 65°C (150°F), 150 g (5.3 oz) tube  
 FDT-HT-GREASE In Stock   ¥1,595.00    Acoustic couplant for sensor mounting, max temperature 200°C (392°F) 56.7 g (2 oz) tube  
 FDT-NS-GREASE 6 Weeks   ¥710.00    Non-silicone acoustic couplant for sensor mounting, 79 g (2.8 oz) tube  
Price are shown in RMB.

 Note: Comes complete with acoustic couplant and operator's manual.


 Ordering Example: (1) FDT-GREASE coupling grease, ¥710.00
   Part Number Builder
(1) (2)   
F
F
D
D
T
T
-
-
Qty:
Option Descriptions
(1) Range LPM (GPM)
  Select
31 for 2 to 100 (0.5 to 25)
32 for 4 to 200 (1 to 55)
33 for 8 to 375 (2 to 100)
34 for 15 to 570 (4 to 150)
35 for 18 to 830 (5 to 220)
36 for 30 to 1500 (8 to 400)
(2) Additional Option
  Select
Nothing(leave field blank) for ANSI carbon steel/stainless steel pipe
-C for Copper pipe applications
-T for Plastic tubing applications
 NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


   
Keywords:Transit-Time Ultrasonic Flow Meter ultra sonic, flow transducer, ultrasonic, ultrasonic flow meter, NONINTRUSIVE, NON-INTRUSIVE, water flow meter, liquid flow sensor, ultrasonic sensing , accelerometer cost digital water flow meters flow rate meters linear slide bearings turbine flowmeters