Easy-View Flowmeters |
FL-9300 Series |
|
|
|
|
|
The FL-9000 Series flowmeter are
rugged, low-cost direct reading
industrial class flowmeters that are
simple to install. They can be
mounted (installed) in any position
from vertical to horizontal without
costly flow straighteners or other
special plumbing. Constructed of high
impact polysulfone plastic, the
product line offers excellent
structural integrity and chemical
compatibility with a wide range of
industrial chemicals.
FL-9000-ACL/DCL
The AC and DC powered flow
switch modules consist of a
latching relay circuit housed in a
sealed polypropylene enclosure.
The modules have a normally open
dry relay contact that can be used to
directly control alarms, warning
lights, relays or be used to interface
to a PLC. The relay will be latched
on as the magnet inside the flow
meter passes by the module, and
remain latched on until the magnet
passes in the other direction or
power is interrupted. The set-point
is adjustable from 0 to 100% of
full scale.
FL-93/96/
97/98/9900
FL-9000-RA/RB/RC
The reed switch modules are
housed in a sealed polypropylene
enclosure. The reed switch module
does not provide the latching
function like the AC and DC
powered units. When the magnet
inside the flowmeter comes within
proximity of the module, the reed
switch will change state. The setpoint
is adjustable from 0 to 100%
full scale. Two reed switches
providing low flow and high flow set
points may be installed on a single
flowmeter.
Specifications
Materials: Polysulfone plastic body, piston and cone, T300 stainless spring, buna flow indicator ring and pressure seals, C360 brass or PVC fittings, polypropylene limit indicators
Fittings/Threads:
NPT: ANSI/ASME B1.20.1
BSPP: ISO228 (-BSP)
Temperature Range: 0 to 121°C (32 to 250°F)
PVC Fittings: 0 to 60°C (32 to 140°F)
Pressure Rating: 22.4 bar (325 psi) maximum
Pressure Drop: See differential pressure chart on right
Accuracy: ±5% of full scale
Repeatability: ±1%
Standard Scaling: 0.876 specific gravity for oil, 1.0 specific gravity for water
Switch Specifications
Power:
FL-9000-ACL: 115 Vac ±10%
FL-9000-DCL: 10 to 30 Vdc
FL-9000-ACL/DCL: 25 mA maximum current
Contacts: 1A @30 Vdc, 0.5A @ 125 Vac (resistive load)
FL-9000-RA: 1 A, 200 Vdc maximum, 15 W (resistive load)
FL-9000-RB/RC: 0.25 A maximum, 175 Vdc, 5 W (resistive load)
Temperature:
FL-9000-ACL/DCL: 0 to 70°C (32 to 158°F)
FL-9000-RA/RB/RC: 0 to 121°C Specifications (32 to 250°F)
|
|
|
|
|
|
† Price are shown in RMB.
Note: Comes complete with operator’s manual. For units with BSPP threads add “-BSP” to model number, no additional cost.
|
|
|
|
|
| |
|
Keywords:EZ-View Flowmeters, easy-view, easy view flow
|
Back to top
|
|
|