Circulation Heater for Steam, Air and Gas Applications to 750°F |
GCHI and GCHIB Series |
|
|
|
|
Steam, Air and Gas Circulation Heater
|
Click for larger image. |
|
|
|
|
3 - 18" ANSI Blind Flange Design
|
|
3 - 18" Carbon Steel Pipe Body, 150 Lb Construction (750°F Max. Vessel and 1600°F Max. Sheath Temp.) 1 For Stainless Steel Pipe Body Construction, Refer to GCHIS Series Circulation Heaters.
|
|
3 - 350 kW
|
|
240 and 480V, 1 & 3 Phase
|
|
General Purpose, Moisture Resistant/Explosion Resistant, Explosion Resistant or Moisture Resistant Terminal Enclosure
|
|
0.475" Dia. INCOLOY Sheath Elements (15 - 23 W/In2 )
|
|
3 and 5" with Side Mounted Thermostat (200 - 550°F), 8, 10, 14 and 16" without Thermostat
|
|
CSA and Other Third Party Approval, Listing or Certification Available
|
View related products - Circulation Heaters
|
| |
|
|
|
APPLICATIONS
Steam, Air and Gas: Higher kW ratings for larger industrial and commercial
gas heating applications.
FEATURES
Terminal Enclosure: E1 General Purpose is standard. E2 Moisture Resistant/Explosion Resistant, E3
Explosion Resistant or E4 Moisture Resistant available.
Elements: 0.475" diameter INCOLOY sheath elements.
Flange: 3 -10" ANSI B-16.5 flange with 1/2" thermowell for thermostat
bulb and a 1/8" NPT threaded opening for a thermocouple or RTD.
Vessel: Pipe body and nozzles are ASTM A53B carbon steel pipe. The end disk is ASTM A516 Grade 70
carbon steel plate. Provided with thermal insulation and painted sheet metal jacket.
Baffle Assembly: Internal baffle assemblies are provided on GCHIB-18 models. Baffles reduce
the internal cross sectional area thereby increasing the velocity of the gas. Increasing the gas
velocity reduces the operating temperature of the elements and the shell of the vessel.
Wiring: Convenient field wiring terminals are provided for easy installation.
Controls: Series 03 and 06 stock and assembly stock heaters come equipped with
side mounted thermostat. Series 18, 27, 45 and 108 are furnished without thermostat.
kW |
Volts |
Ckt & Phase |
Dimensions (In.) |
Model No . |
Wt. (Lbs.) |
A |
B |
C |
Series 03 — 3 inch, 150 lb carbon steel vessel — 3 INCOLOY elements1 (23 W/In2) with thermostat |
3 | 240 | 1-1 | 32 15/16 | 22 1/2 | 16 1/2 | GCHI-03-003P-E1/240 | 62 |
3 | 240 | 1-3 | 32 15/16 | 22 1/2 | 16 1/2 | GCHI-03-003P-E1/240/3P | 62 |
3 | 480 | 1-1 | 32 15/16 | 22 1/2 | 16 1/2 | GCHI-03-003P-E1/480 | 62 |
3 | 480 | 1-3 | 32 15/16 | 22 1/2 | 16 1/2 | GCHI-03-003P-E1/480/3P | 62 |
4.5 | 240 | 1-1 | 32 15/16 | 22 1/2 | 16 1/2 | GCHI-03-04P5-E1/240 | 72 |
4.5 | 240 | 1-3 | 32 15/16 | 22 1/2 | 16 1/2 | GCHI-03-04P5-E1/240/3P | 72 |
4.5 | 480 | 1-1 | 32 15/16 | 22 1/2 | 16 1/2 | GCHI-03-04P5-E1/480 | 72 |
4.5 | 480 | 1-3 | 32 15/16 | 22 1/2 | 16 1/2 | GCHI-03-04P5-E1/480/3P | 72 |
6 | 240 | 1-1 | 42 15/16 | 32 1/2 | 26 1/2 | GCHI-03-006P-E1/240 | 94 |
6 | 240 | 1-3 | 42 15/16 | 32 1/2 | 26 1/2 | GCHI-03-006P-E1/240/3P | 94 |
6 | 480 | 1-1 | 42 15/16 | 32 1/2 | 26 1/2 | GCHI-03-006P-E1/480 | 94 |
6 | 480 | 1-3 | 42 15/16 | 32 1/2 | 26 1/2 | GCHI-03-006P-E1/480/3P | 94 |
1. Outlet gas temperature must be kept below both maximum sheath and vessel temperature
or element and heater damage may occur.
kW |
Volts |
Ckt & Phase |
Dimensions (In.) |
Model No . |
Wt. (Lbs.) |
A |
B |
C |
Series 06 — 5 inch, 150 lb carbon steel vessel — 6 INCOLOY elements1 (23 W/In2) with thermostat |
9 | 240 | 1-1 | 41 3/4 | 30 | 11 3/8 | GCHI-06-009P-E1/240 | 135 |
9 | 240 | 1-3 | 41 3/4 | 30 | 11 3/8 | GCHI-06-009P-E1/240/3P | 135 |
9 | 480 | 1-1 | 41 3/4 | 30 | 11 3/8 | GCHI-06-009P-E1/480 | 135 |
9 | 480 | 1-3 | 41 3/4 | 30 | 11 3/8 | GCHI-06-009P-E1/480/3P | 135 |
12 | 240 | 1-1 | 48 3/4 | 37 | 14 7/8 | GCHI-06-012P-E1/240 | 164 |
12 | 240 | 1-3 | 48 3/4 | 37 | 14 7/8 | GCHI-06-012P-E1/240/3P | 164 |
12 | 480 | 1-1 | 48 3/4 | 37 | 14 7/8 | GCHI-06-012P-E1/480 | 164 |
12 | 480 | 1-3 | 48 3/4 | 37 | 14 7/8 | GCHI-06-012P-E1/480/3P | 164 |
20 | 240 | 1-1 | 60 1/4 | 48 1/2 | 20 5/8 | GCHI-06-020P-E1/240 | 195 |
20 | 240 | 1-3 | 60 1/4 | 48 1/2 | 20 5/8 | GCHI-06-020P-E1/240/3P | 195 |
20 | 480 | 1-1 | 60 1/4 | 48 1/2 | 20 5/8 | GCHI-06-020P-E1/480 | 195 |
20 | 480 | 1-3 | 60 1/4 | 48 1/2 | 20 5/8 | GCHI-06-020P-E1/480/3P | 195 |
25 | 240 | 1-1 | 73 5/8 | 61 7/8 | 27 5/16 | GCHI-06-025P-E1/240 | 212 |
25 | 480 | 1-3 | 73 5/8 | 61 7/8 | 27 5/16 | GCHI-06-025P-E1/480/3P | 212 |
25 | 240 | 1-1 | 73 5/8 | 61 7/8 | 27 5/16 | GCHI-06-025P-E1/240 | 212 |
25 | 480 | 1-3 | 73 5/8 | 61 7/8 | 27 5/16 | GCHI-06-025P-E1/480/3P | 212 |
30 | 240 | 1-3 | 86 5/8 | 74 7/8 | 33 7/8 | GCHI-06-030P-E1/240/3P | 240 |
30 | 480 | 1-3 | 86 5/8 | 74 7/8 | 33 7/8 | GCHI-06-030P-E1/480/3P | 240 |
Series 18 — 8 inch, 150 lb carbon steel vessel — 18 baffled INCOLOY elements1 (20 W/In2) |
30 | 240 | 3-3 | 54 5/16 | 32 11/16 | 29 3/16 | GCHIB-18-030P-E1/240 | 350 |
30 | 480 | 3-3 | 54 5/16 | 32 11/16 | 29 3/16 | GCHIB-18-030P-E1/480 | 350 |
40 | 240 | 3-3 | 61 5/16 | 39 11/16 | 36 3/16 | GCHIB-18-040P-E1/240 | 420 |
40 | 480 | 3-3 | 61 5/16 | 39 11/16 | 36 3/16 | GCHIB-18-040P-E1/480 | 420 |
50 | 240 | 3-3 | 68 15/16 | 47 5/16 | 43 3/16 | GCHIB-18-050P-E1/240 | 480 |
50 | 480 | 3-3 | 68 15/16 | 47 5/16 | 43 3/16 | GCHIB-18-050P-E1/480 | 480 |
Series 27 — 10 inch, 150 lb carbon steel vessel — 27 INCOLOY® elements1 (15 W/In2) |
50 | 240 | 3-3 | 68 9/16 | 43 | 39 1/2 | GCHI-27-050P-E1/240 | 400 |
50 | 480 | 3-3 | 68 9/16 | 43 | 39 1/2 | GCHI-27-050P-E1/480 | 400 |
60 | 240 | 3-3 | 75 9/16 | 50 | 46 1/2 | GCHI-27-060P-E1/240 | 440 |
60 | 480 | 3-3 | 75 9/16 | 50 | 46 1/2 | GCHI-27-060P-E1/480 | 440 |
70 | 240 | 3-3 | 81 9/16 | 56 | 52 1/2 | GCHI-27-070P-E1/240 | 480 |
70 | 480 | 3-3 | 81 9/16 | 56 | 52 1/2 | GCHI-27-070P-E1/480 | 480 |
80 | 240 | 3-3 | 91 9/16 | 66 | 62 1/2 | GCHI-27-080P-E1/240 | 520 |
80 | 480 | 3-3 | 91 9/16 | 66 | 62 1/2 | GCHI-27-080P-E1/480 | 520 |
90 | 240 | 3-3 | 100 9/16 | 75 | 71 1/2 | GCHI-27-090P-E1/240 | 560 |
90 | 480 | 3-3 | 100 9/16 | 75 | 71 1/2 | GCHI-27-090P-E1/480 | 560 |
1. Outlet gas temperature must be kept below both maximum sheath and vessel temperature
or element and heater damage may occur. Other Note — Refer to the Controls section
for side mounted controls or control panels.
kW |
Volts |
Ckt & Phase |
Dimensions (In.) |
Model No . |
Wt. (Lbs.) |
A |
B |
C |
D |
E |
Series 45 — 14 inch, 150 lb carbon steel vessel — 45 INCOLOY elements1 (15 W/In2) |
75 | 480 | 3-3 | 76 | 57 3/16 | 66 11/16 | 15 | 11 1/2 | GCHI-45-075P-E1/480 | 835 |
90 | 480 | 3-3 | 76 | 57 3/16 | 66 11/16 | 15 | 11 1/2 | GCHI-45-090P-E1/480 | 925 |
125 | 480 | 3-3 | 91 | 72 3/16 | 81 11/16 | 15 | 11 1/2 | GCHI-45-125P-E1/480 | 1025 |
150 | 480 | 3-3 | 106 | 87 3/16 | 96 11/16 | 15 | 11 1/2 | GCHI-45-150P-E1/480 | 1125 |
175 | 480 | 3-3 | 121 | 102 3/16 | 111 11/16 | 15 | 11 1/2 | GCHI-45-175P-E1/480 | 1225 |
Series 72 — 16 inch, 150 lb carbon steel vessel — 72 INCOLOY elements1 (15 W/In2) |
200 | 480 | 3-3 | 93 | 74 5/8 | 84 1/8 | 16 | 12 3/4 | GCHI-72-200P-E1/480 | 1265 |
225 | 480 | 3-3 | 101 | 82 5/8 | 92 1/8 | 16 | 12 3/4 | GCHI-72-225P-E1/480 | 1310 |
250 | 480 | 3-3 | 109 | 90 5/8 | 100 1/8 | 16 | 12 3/4 | GCHI-72-250P-E1/480 | 1355 |
Series 108 — 18 inch, 150 lb carbon steel vessel — 108 INCOLOY elements1 (15 W/In2) |
300 | 480 | 6-3 | 94 | 75 1/2 | 85 | 17 | 13 1/2 | GCHI-108-300P-E1/480 | 1400 |
325 | 480 | 6-3 | 100 | 81 1/2 | 91 | 17 | 13 1/2 | GCHI-108-325P-E1/480 | 1450 |
350 | 480 | 6-3 | 106 | 87 1/2 | 97 | 17 | 13 1/2 | GCHI-108-350P-E1/480 | 1500 |
1. Recommended temperature limits for all GCH heaters with carbon steel vessels
and INCOLOY elements are 1600oF maximum for the sheath temperature and
750°F maximum for the vessel temperature at 5 psi pressure maximum. Exceeding
these recommendations will void the factory warranty. Outlet gas temperatures must
be kept below both the maximum sheath and vessel temperature or element and
vessel damage may occur. Heaters supplied without controls.
Other Note — Refer to the Controls section for side mounted controls or control panels.
|
|
|
|
|
|
† Price are shown in RMB.
|
|
|
|
|
|
|
|
|
Part Number Builder |
|
|
|
|
|
|
Option Descriptions
|
(1)
|
Series
|
|
Select GCHI for GCHI Series GCHIB for GCHIB Series
(2)
|
Number of Elements
|
|
Select 03 for 3 Elements 06 for 6 Elements 18 for 18 Elements 27 for 27 Elements 45 for 45 Elements 72 for 72 Elements 108 for 108 Elements
(3)
|
Wattage
|
|
Select 003P for 3 kW 04P5 for 4.5 kW 006P for 6 kW 009P for 9 kW 012P for 12 kW 020P for 20 kW 025P for 25 kW 030P for 30 kW 040P for 40 kW 050P for 50 kW 060P for 60 kW 070P for 70 kW 075P for 75 kW 080P for 80 kW 090P for 90 kW 125P for 125 kW 150P for 150 kW 200P for 200 kW 225P for 225 kW 250P for 250 kW 300P for 300 kW 325P for 325 kW 350P for 350 kW
(4)
|
Voltage
|
|
Select 240 for 240 V 480 for 480 V
(5)
|
Power
|
|
Select Nothing(leave field blank) for 1 Phase Power /3P for 3 Phase Power
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| | | |
|
|
|
|
|
| |
|
Keywords:Steam, Air and Gas Applications to 750°F, Circulation Heater
|
Back to top
|
|
|