Low Noise Thermocouple Probes with High Temperature Miniature Connectors |
HG(*)MQIN and HG(*)MQSS Series |
|
|
|
|
|
|
|
|
Connector Body Temperature Ratings: with Ferrite Cores: 120°C (250°F) Without Ferrite Cores: 260°C (500°F)
|
|
Environmentally Friendly Cadmium-Free Liquid Crystal Polymer Material
|
|
Mating Connector, Cable Clamp, Write-On Windows and Ground Strap Sold Separately!!
|
|
Ground Strap Connection Provides Protection Against Electrical Noise
|
|
Made with Special Limits of Error Material
|
|
Ground Strap Provides Additional Mechanical Rigidity
|
|
Write-on Areas for Easy Identification on Female Connector and Male Probe Connector
|
|
Compatble with Miniature Style Probes and Connectors
|
|
Ferrite Core Impedance (±20%) 55 ohms @ 25 mHz 90 ohms @ 100 mHz
|
View related products - Thermocouples
|
| |
|
|
|
The OMEGA ® low noise thermocouple probes and connectors maintain an electri-cal connection from the sheath of the probe, through the connectors, all the way to your instrumentation.
This system assures high accuracy measurements, providing protection against electrical noise. The external strap maintains the electrical connection of the ground wire, and also strengthens the mechanical connection between the two connectors. The female connector features a handy write-on area, for easy identification.
Examples of models listed in "To order" box below. Use Part Number Builder (below) or view pdf file for pricing on all available models.
View the Thermocouple Accuracy and Color Code charts
|
|
|
|
|
|
† Price are shown in RMB.
Note: Consult Sales for Pricing on Special Configurations.
Ordering Example: (1) HGKMQSS-040G-6 Subminiature quick disconnect probe, type K, stainless steel sheath, 0.040, ¥595.00
|
|
|
|
|
|
|
|
|
Part Number Builder |
|
|
|
|
|
|
Option Descriptions
|
(1)
|
Thermocuple Type
|
|
Select JMQ for J Type KMQ for K Type EMQ for E Type TMQ for T Type
(2)
|
Sheath Material
|
|
Select SS for Stainless Steel IN for Inconnel
(3)
|
Sheath Diameter
|
|
Select 040 for .040 Inches 062 for .062 Inches 125 for .125 Inches
(4)
|
Thermocouple Termination
|
|
Select G for Grounded to Sheath U for Ungrounded E for Exposed Tip
(5)
|
Sheath Length
|
|
Select 6 for 6 Inches 12 for 12 Inches. Other lengths available on request to Sales Dept
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| | | |
|
|
|
|
|
| |
Related Links -
Related Products
|
|
|
|
|
|
|