Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation
800-819-0559 (Landline) | 400-619-0559 (Cell)
Home >> pH and Conductivity... >> Industrial pH Instru... >> pH Panel Mount Contr... >> PHUCN601, PHUCN610, PHUTX601

pH, ORP and Conductivity Controller and Transmitter

PHUCN601, PHUCN610, PHUTX601   
1 year warranty
 
pH, ORP and Conductivity Controller and Transmitter
PHUCN601, PHUCN610, PHUTX601:pH, ORP and Conductivity Controller and Transmitter
Click for larger image.
   
For pH, ORP, Conductivity/Resistivity
1/4 DIN, NEMA 4X, Polycarbonate Enclosure
User-Friendly Design with Interior LCD Menu
Easy to Read with Large, Bright LED Display
Quick and Easy to Calibrate
Reduces Chemical Consumption with Cycle Timed Relays on Controllers
Two Control Relays with Third Relay for High/Low Alarm on Controllers

View related products - Industrial pH Instrumentation and Electrodes

Click to scroll below to order See Specs PDF Manuals View a printer friendly page

The PHUCN600 Series multi-parameter controller is a microprocessor-based controller capable of measuring one of the following parameters, pH, ORP, or conductivity.
When shipped from the factory, the PHUCN600 Series is not set to measure any one parameter.When the PHUCN600 Series is powered up for the first time, it will display the meter selection screen where the meter type must be selected. This meter selection screen will only be displayed when the PHUCN600 Series is powered up for the first time.
After the user selects a meter type the PHUCN600 Series will remain set to that meter type until it is changed with the meter selection menu function in the Utilities menu.
To return the PHUCN600 Series to its factory settings, the user must re-select the current meter type from the meter selection menu function. This will override all set-points and return all settings back to the factory settings. The PHUCN600 Series User’s menu has been divided into five main categories:
  • Calibration, used to calibrate the PHUCN600 Series with the selected sensor
  • Utilities, used to manually control or override the outputs
  • Setup, used to configure the PHUCN600 Series many options
  • Diagnostics, used to troubleshoot any problems
  • Outputs, used to configure the PHUCN600 Series outputs.
There are two displays on the PHUCN600 Series. A bright LED numeric display with bar graph on the outside front panel, and a 2-line, 16-character LCD display on the inside. The LED readout on the outside panel can be seen several yards away. The distinctive, Color coded bar graph will immediately indicate if you are within the process parameters that you set (green), if the control relays are on (yellow) and if you are in alarm condition (red). This makes diagnosing pump and alarm malfunctions easy. All configuration and control functions are performed on the LCD menu on the inside front panel.
A universal mounting kit is included for surface, panel and pipemount applications. The 1/4" DIN enclosure makes panel-mount cutouts and engineering simple.
Complete and versatile the PHUTX600 is the 1/4 DIN two wire transmitter which can measure Conductivity, pH or ORP. PHUTX600 comes complete with a universal mounting kit for surface, panel and pipe-mount applications. The NEMA 4X 1/4 DIN enclosure is perfect for stand-alone or panel-mount operation.
PHUCN600 and PHUTX600 Series are packaged in a rugged NEMA 4X polycarbonate enclosure making it ideally suited for heavy-duty applications such as industrial wastewater neutralization, municipal water and wastewater, pulp and paper, and process control.

The PHE-600-SB Salt Bridge kit required for use of the pH and ORE sensors is sold separately. pH and ORE sensors can not be used without the Salt Bridge kit.

Order on www.omegaengineering.cn and 5% will be discounted when you checkout.
  To Order (Specify Model Number)
All list prices are pre-VAT rate not including tax and shipping
 
 Part Number   Availability   Price(RMB)   Description    Qty.
 Controllers
 PHUCN601    Consult sales   120 Vac pH/ORP conductivity  
 PHUCN610    Consult sales   240 Vac pH/ORPconductivity  
 Transmitter
 PHUTX601    Consult sales   Transmitter pH/ORP conductivity  
 Electrodes with 1 1/2 NPT, 4.6 m (15') 5 conductor shielded cable, -5 to 95°C (23 to 203 °F)
 PHE-600    Consult sales   1 1/2 NPT differential pH electrode, PPS sensor body 180 mm (7.1") long 55 mm (2.14") diameter  
 ORE-600 2 Weeks   ¥6,485.00    1 1/2 NPT differential ORP electrode, PPS sensor body 180 mm (7.1") long 55 mm (2.14") diameter  
 Electrodes with 1 1/4" compression fitting for variable insertion, 4.6 m (15') 5 conductor shielded cable, -5 to 95°C Wetted materials: CPVC PVDF glass titanium palladiam alloy and EPDM (platinum for ORP probe) psig max: 6.9 bar (100 psig)
 PHE-610 2 Weeks   ¥7,365.00    Compression fitting pH electrode for 7/8" to 5" variable insertion, 229 mm (9") long, 28 mm (1.125") diameter  
 ORE-610 10 Weeks   ¥6,690.00    Compression fitting ORP electrode for 7/8" to 5" variable insertion  
 PHE-620 6 Weeks   ¥7,365.00    Hot tap pH electrode for extended lengths 7/8" to 6" variable insertion  
 ORE-620 10 Weeks   ¥7,210.00    Hot tap ORP electrode for extended lengths 7/8" to 6" variable insertion  
 Conductivity cells with 3/4 MNPT CPVC compression fitting, auto. temp. Compensation: 0 to 100°C (32 to 212°F). Wetted materials:Graphite, epoxy, EPDM,& CPVC Max. Press/Temp: 50 psi @60°C, 100 psi @ 50°C, 150 psi @ 20°C cable length: 6.10 m (20')
 CDE-600-001 6 Weeks   ¥3,400.00    0.01 cell constant 0 to 2 µS/cm and 0 to 19.99 MΩ/cm epoxy low temp cond probe  
 CDE-600-01 6 Weeks   ¥2,230.00    0.1 cell constant 0 to 20 & 0 to 200 µS/cm epoxy low temp cond probe  
 CDE-600-1 2 Weeks   ¥2,230.00    1 cell constant 0 to 2000 µS/cm epoxy low temp cond probe  
 CDE-600-10 6 Weeks   ¥2,230.00    10 cell constant 0 to 20 mS/cm epoxy low temp cond probe  
 CDE-600-50 6 Weeks   ¥2,435.00    50 constant 0 to 200 mS/cm epoxy low temp cond probe  
 Conductivity cells with 3/4 MNPT 316SS compression fitting, auto. temp. Compensation: 0 to 100°C (32 to 212°F). Wetted materials: Graphite, epoxy, polypropylene, & 316SS Max. Press/Temp: 250psi @ 120°C cable length: 6.10 m (20')
 CDE-610-001 6 Weeks   ¥4,185.00    0.01 cell constant 0 to 2 µS/cm & 0 to 19.99 MΩ/cm epoxy high temp cond probe  
 CDE-610-01 2 Weeks   ¥3,190.00    0.1 cell constant 0 to 20 and 0 to 200 µS/cm epoxy high temp cond probe  
 CDE-610-1 2 Weeks   ¥3,190.00    1 cell constant 0 to 2000 µS/cm epoxy high temp cond probe  
 CDE-610-10 6 Weeks   ¥3,190.00    10 cell constant 0 to 20 mS/cm epoxy high temp cond probe  
 CDE-610-50 6 Weeks   ¥3,400.00    50 cell constant 0 to 200 mS/cm epoxy high temp cond probe  
 Required for Use of pH and ORE Sensors
 PHE-600-SB 6 Weeks   ¥1,765.00    † Salt Bridge kit kit with PVDF outer junction (3 pack) for required for use with PHE/ORE-600 Series sensors  
 PHE-612-SB 2 Weeks   ¥1,765.00    † Salt Bridge kit with PVDF outer junction (3 pack) for PHE/ORE-610/620 Series sensors  
 pH Accessories
 PHE-600-C-(*)    Consult sales   $3.00/foot Interconnect cable for PHE/ORE-600 Series  
 PHE-600-EP 6 Weeks   ¥1,765.00    Electrode protector  
 PHE-600-JB 6 Weeks   ¥1,205.00    Junction box with integrated terminal strip.  
 PHE-610-EP    Consult sales   Electrode protector for PHE/ORE-610/620  
 PHE-620-BVA    Consult sales   PVC hot tap ball valve assembly  
 PHA-10 2 Weeks   ¥154.00    pH 10 buffer solution 500 ml (1 pt)  
 PHA-10-GAL 2 Weeks   ¥384.00    pH 10 buffer solution 4L (1 gal)  
 PHA-4 2 Weeks   ¥146.00    pH 4 buffer solution 500 ml (1 pt)  
 PHA-4-GAL 2 Weeks   ¥364.00    pH 4 buffer solution 4 L (1 gal)  
 PHA-7 2 Weeks   ¥146.00    pH 7 buffer solution 500 ml (1 pt)  
 PHA-7-GAL 2 Weeks   ¥364.00    pH 7 buffer solution 4 L (1 gal)  
 PHA-DI 2 Weeks   ¥182.00    De-ionized water 500 ml (1 pt)  
 PHA-DI-GAL 3 Weeks   ¥430.00    De-ionized water 4 L (1 gal)  
 PHAB-DI 4 Weeks   ¥390.00    20 single use foil packets of de-ionized water  
 PHAB-PH 2 Weeks   ¥390.00    5 each single use foil packets of pH-4, pH-7, pH-10, and de-ionized water  
Price are shown in RMB.

 Note: Comes complete with operators manual.

* Insert cable length in feet.

†The PHE-600-SB Salt Bridge kit required for use of the pH and ORE sensors is sold separately. pH and ORE sensors can not be used without the Salt Bridge kit.



 Related Links - Manual
 Product Manual
   Download  PHUCN600 - Multi-Parameter Controller & Analyzer (NOTE: 40MB)
   Download  PHUTX601 - Multi-Parameter Transmitter (NOTE: 21MB)
   Download  PHE--600/610, ORE-600/610 - Differential pH and ORP Probes
   Download  CDE-600/610 - Conductivity Cells
   
Keywords:pH, ORP and Conductivity Controller and Transmitter, 30 amp terminal block electrical push buttons electronic sensor vacuum pressure switch