The OMEGA™ iTH Series
instruments monitor and control both
temperature and relative humidity. All
controllers in the series
are high quality, highly accurate
instruments featuring Omega’s
award-winning iSeries technology,
uncompromising accuracy, backed by
an extended 5-year warranty.
The instruments are simple to
configure and use, while providing
tremendous versatility and a wealth
of powerful features.
With two full channels of PID control, these instruments are the perfect choice for environmental control applications such as test chambers, clinical storage, computer rooms, etc.
The iTH Series Controllers provide
single output control for humidity
and temperature and are easily
programmed for any control or
alarming requirement from simple
on-off to full autotune PID control.
The iTH family controllers are available in four true
DIN sizes: the ultra compact 1/32 DIN;
the popular midsize 1/16 DIN square
bezel with dual display; the 1/8 DIN
vertical, and the 1/8 DIN horizontal with
the big bright 21 mm digits.
The iTH Series LED displays
can be programmed to change color
between GREEN, AMBER, and RED at any setpoint or alarm point.
The iTH controller models offer a
choice of 2 control or alarm outputs
in almost any combination: solid state
relays (SSR); form “C” SPDT (single
pole double throw) relays; pulsed 10
Vdc output for use with an external
SSR; or analog output selectable
for control or retransmission of the
process value.
The networking and communications
options (highly recommended)
include direct Ethernet LAN
connectivity with an embedded Web
server, and serial communications.
The C24 serial communications
option includes both RS232 and
RS485. Protocols include both
MODBUS® and a straightforward
ASCII protocol. The C4EIT option
includes both Ethernet and RS485
ASCII/MODBUS on one device.
The iTH Series
controllers are designed for easy
integration with popular industrial
automation, data acquisition and
control programs as well as Microsoft
Visual Basic and Excel. Omega
provides free configuration software
which makes it fast and easy to get up
and running. Available for download
on the Web.
|
SPECIFICATIONS
Accuracy |
Range |
Range |
+/-4%RH |
0%-5% RH   , |
95%-100% RH |
+/-3.5%RH |
5%-10% RH   , |
90%-95% RH |
+/-3%RH |
5%-10% |
|
Control
Action: Reverse (heat) or direct (cool)
Modes: Time and amplitude proportional control modes; selectable manual or auto PID, proportional, proportional with integral, proportional with derivative with anti-reset windup and ON/OFF
Rate: 0 to 399.9 seconds
Reset: 0 to 3999 seconds
Cycle Time: 1 to 199 seconds; set to 0 for ON/OFF operation
Gain: 0.5 to 100% of span; setpoints 1 or 2
Damping: 0000 to 0008
Soak: 00.00 to 99.59 (HH:MM), or OFF
Ramp to Setpoint: 00.00 to 99.59 (HH:MM), or OFF
Autotune: Operator initiated from front panel for 1 input at a time only
Outputs
There are two physical outputs: Output 1 = RH, Output 2 = Temp
Functions are set up as Outputs (PID or ON/OFF), or Alarms
Ordering output choices:
Relay: 250 Vac @ 3A or 30 Vdc @ 3A (resistive load); Form C SPDT
SSR: 20 to 265 Vac @ 0.05 - 0.5A (resistive load); continuous
DC Pulse: Non-Isolated; 10 Vdc @ 20 mA (used with external SSR)
Analog Output (Output 1 only): Non-Isolated, control or retransmission 0 to 10 Vdc or 0 to 20 mA;
500 ohm max, accuracy is ±1% of FS
Control Output 1 and 2
Operation:
Action: Reverse (heat) or Direct (cool)
Modes: Time and Amplitude Proportional Control Modes; selectable Manual or Auto PID, Proportional, Proportional with Integral, Proportional with Derivative with Anti-reset Windup and ON/OFF
Alarm 1 and 2 (Programmable)
1) Alarms are used for color changing sequence of alarm status (visual alarm).
2) Alarm functions are active, in addition to the color changing functions, if Output 1 & 2 are (menu) disabled.
3) If Alarms are disabled, Output menus (PID or ON/OFF) are active. Color change is still active.
Operation: High/low, above/below, band, latch/unlatch, normally open/normally closed and process/deviation; front panel configurations
-AL Limit Alarm Version: Output 1 & 2 submenus used for PID are eliminated from menu. Color sequence based on alarm setpoints is still available.
Input
Relative Humidity Accuracy/Range: ±3% for 10 to 90%; ±3.5% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100%
Hysteresis: ±1% RH
Non-linearity: ±3%
Temperature Accuracy/Range*:
±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F)
Resolution: 0.1%, 12-bit for RH; 0.1°C, 14 bit for temperature
Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature
* Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C.
Network and Serial Communications (For Options -C24, -C4EIT, -EIT)
Ethernet: Standards compliance IEEE 802.3 10Base-T
Supported Protocols: TCP/IP, ARP
RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status
RS485: Addressable from 0 to 199
Connection: Screw terminals
General
A/D Conversion: 12-bit RH and 14-bit temp
Reading Rate: 2 samples per sec max
Digital Filter: Programmable
Decimal Selection: None, 0.1 for temp and humidity
Display: 4-digit, 9-segment LED
i32, i16D, i8DV: 10.2 mm (0.40")
i8: 21 mm (0.83")
i8DH: 10.2 mm (0.40") and 21 mm (0.83") GREEN, AMBER, and RED programmable colors for process variable, setpoint and temp units
Operating Temperature: 0 to 50°C (32 to 122°F), 90% RH non-condensing
Protection:
i32, i16D: NEMA 4X (IP65) front bezel
i8DH, i8DV: NEMA 1 (IP23) front bezel
Power: Refer to ordering guide
No CE compliance above 60 Hz.
|
|
|
|
|
|
|
† Price are shown in RMB.
Note: 1. Analog output (Option 5) is not available with "-AL" units. 2. "-C4EIT" or "-EIT" option is not available on the 1/32 DIN. Refer to the iServer section for other Ethernet devices that can connect to a CNiTH-i32xx-x-C24. Units can be powered safely with 24 Vac power, but no certification for CE/UL are claimed.
Ordering Example: (1) CNiTH-i8DH43-5-C4EIT is a horizontal 1/8 DIN dual display with pulse and relay outputs, a 5, ¥7,250.00,
|
|
|
|
|
|
|
|
|
Part Number Builder |
|
|
|
|
|
|
Option Descriptions
|
(1)
|
Size
|
|
Select -i8DH for 1/8 DIN Dual Display Horizontal -i8DV for 1/8 DIN Dual Display Vertical -i16D for 1/16 DIN Dual Display -i32 for 1/32 DIN Single Display
(2)
|
Control Outputs
|
|
Select 22 for 2 Solid State Relays SSR 23 for SSR and Form C Relay 24 for SSR and Pulse 10V dc 33 for 2 Relays - Form C Relay 42 for Pulsed 10 V dc and SSR 43 for Pulsed 10 V dc and Form C Relay 44 for 2 Pulsed 10 V dc 52 for Analog Output and SSR 53 for Analog output and Relay 54 for Analog output and Pulse
(3)
|
RH/Temp Probe
|
|
Select -2 for 2 in. probe with 3ft cable -5 for 5 in. probe with 10ft cable
(4)
|
Network Options
|
|
Select Nothing(leave field blank) for no Network Option -C24 for Isolated RS232 and RS485 -EIT for Ethernet with Embedded Web Server -C4EIT for Ethernet with Embedded Web Server + Isolated RS485/422
(5)
|
Power Supply
|
|
Select Nothing(leave field blank) for Standard power input 90-240Vac -DC for Low Power option 12-36 Vdc/24 Vac CNiTH-i32 or 20-36 Vdc/24 Vac CNiTH-i8/i16
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| | | |
|
|
|
|
|
| |
Related Links -
Manual, Related Products
|
|
|
Product Manual
|
Download
CNiTH-i8DH & CNiTH-i8DV - Quick Start Manual Humidity + Temp Controller
|
Download
CNiTH-i32 iSeries - Quick Start Manual - Humidity + Temperature Controller
|
Download
CNiTH-16D iSeries - Quick Start Humidity + Temp Controller
|
Download
CNiTH-i8DH, i8DV, i16D, i32 - Temperature + Humidity Controller Manual
|
Download
CNi/CNiS/CNiTH 8,8C,8D,16,16D - -EIT/-C4EIT Option - Embedded Ethernet for iSeries Monitor/Controller
|
Related Products
|
|
OEG_Software:
|
Omega Data Logging & Monitoring Software (OEG) w/ OPC UA/DA
|
|
|
|
|
|
|
|
|