The new CDCN-90A is specifically designed to monitor and control conductivity levels of aqueous solutions. The compact 1 /4 DIN enclosure is NEMA 4X/IP65 rated and ideal for installations with limited space. Modular output cards can be customized to meet your requirements and are field installable. Output options include 4 to 20/0 to 20 mA, 0 to 5/0 to 10 Vdc card, 2 relay card and dual proportional relay card. Relays can be separately configured to operate as HI or LO alarms or proportional relays can be set for pulse rates from 1 to 120 pulses per minute. All functions are easily accessed and programmed from the front keypad. The two-line LCD features a 4 1 /2 digit main display and eight character alphanumeric line that provides calibration, setup, and operation instructions. Standard displays include conductivity and relay status information. Display options include µS, mS or ppm. In addition solution temperature can be quickly accessed with the touch of a button.
Please download the PDF file below for full product specifications
SPECIFICATIONS Controller Conductivity Range: 1 to 400,000µS Resistivity Range: 10k ohm to 18.3m ohm Isolation: 500 Vdc Sensor Compatibility: CDCE-90 Series Display: Upper, 4 1 /2 digit, 0.5" H; Lower 8 digit 0.3" H, 4 relay status annunciation Display Accuracy: ±1% of reading Output Accuracy: ±0.5% FS Memory Backup: Non-volatile RAM Temperature Compensation: Automatic Pt1000 Enclosure Material: ABS plastic Rating: NEMA-4X/IP65 front Power Requirements: 17 to 30 Vdc @ 0.5 A max. and or 90 to 132 Vac or 180 to 264 Vac (jumper selectable) Noise Immunity: Meets IEC 801-2 level 3, IEC 801-3, level 2 Ambient Conditions Operating Temperature: 0 to 55°C (32 to 131°F) Relative Humidity: 95% max. non-condensing Optional Output Cards PHOR-90-R2 Dual Relay Card Contacts: 2 SPDT output Rating: 5 A @ 250 Vac or 30 Vdc maximum resistive load PHOR-90-PC Dual Proportional Relay Card Contacts: 2 SPST 5 A @ 250 Vac, 30 Vdc maximum resistive load (For use with 2 pulse frequency metering pumps. See pages H-3 to H-11 for details) PHOR-90-MA-I 4 to 20/0 to 20 mA Output Card Response Time: 2.5 sec for 100% Maximum Loop Resistance: 425 ohms Isolation: 500 Vdc PHOR-90-5V-I/PHOR-90-10V-I 0 to 5/0 to 10 Vdc Output Card Response Time: 2.5 sec for 100% Minimum Load Resistance: 1 K ohm Isolation: 500 Vdc
|
|
|
 |
|
 |
† Price are shown in RMB.
Note: Each unit is supplied with complete operator’s manual. Conductivity cells must be ordered separately.
Ordering Example: (1) CDCE-90-1 conductivity cell K=1, ¥3,980.00,
|
|
 |
|
 |
|  |