High Standard Accuracy 0.08% BSL included Linearity, Repeatability and Hysteresis
|
|
NEW! High Accuracy Options 0.05% Accuracy Option, add Suffix "-EH" 0.03% Linearity Option, add Suffix "-XL"
|
|
5-Point NIST Traceable Calibration Included with All Models
|
|
Available in Calibrated Units of inHg or hPa (mbar)
|
|
Now Available with M12 Connector, Order Model PX459 (See Part Number Builder at bottom of page)
|
View related products - Pressure Transducers
|
| |
|
|
|
Omega’s PX409 series electronic
barometers are high-accuracy
barometers available in three inHg ranges or three hPa (mbar) ranges:
16 to 32 inHg, 26 to 32 inHg, 0 to 32 inHg or 0 to 1100 hPa,
550 to 1100 hPa or 880 to 1100 hPa (absolute pressure)
for laboratory or industrial test
applications. Models with integral
cables (PX409) are IP67 while
connector styles (PX419 and PX429)
are IP65 rated. They feature all
stainless steel construction, which
makes them ideal for harsh industrial
environments. Their high operating
temperature, broad compensated
range, and excellent temperature
compensation allow stable readings
in applications with fluctuating
temperatures commonly found
where barometric pressure must be
monitored. Models are available
with millivolt, voltage or current
outputs.
The PX409 Barometric series is also available with a USB output and related software. Please see the PX409-USB as possible alternatives or contact our Pressure Engineering department.
SPECIFICATIONS
Output:
Millivolt: 10 mV/V (100 mV @ 10 Vdc)
Amplified Voltage: 0 to 5 Vdc
Current Loop: 4 to 20 mA
Power Requirements:
Millivolt: 5 to 10 Vdc (5 mA @ 10 Vdc)
Amplified Voltage: 10 to 30 Vdc @ 10 mA
Current Loop: 9 to 30 Vdc [max loop res = (Vs-9) x 50]; [9 to 20 Vdc above 105°C (229°F)]
Accuracy (Combined Linearity, Hysteresis and Repeatability): ±0.08% BSL
Zero & Span Balance: Ranges > 5 psi: ±0.5% FS Ranges ≤5 psi 1% max
Span Setting: ±0.5% FS typical, 1% max; calibrated in vertical direction with fitting down
Operating Temperature Range: -45 to 121°C (-49 to 250°F) [-45 to 115°C (-49 to 240°F) for voltage or current outputs]
Compensated Temperature:
Range: 0 - 32 inHg: -29 to 85°C (-20 to 185°F)
Ranges: 16-32, 26-32 inHg: -18 to 85°C (0 to 185°F)
Thermal Effects Zero (Over Compensated Range): ±0.5% span (±1% for 26 to 32 inHg range)
Thermal Effects Span (Over Compensated Range): ±0.5% span (±1% for 26 to 32 inHg range)
Long Term Stability (1-Year): ±0.1% FS typical
Shock: 50 g, 11 ms half sine, vertical and horizontal axis
Vibration: 5-2000-5 Hz 30 minute cycle, Curve L Mil-Spec 810 figure 514-2-2, horizontal and vertical axis
Response Time: <1 ms
Bandwidth: DC to 1 kHz typical
Proof Pressure: 400% of span
Burst Pressure: 1000 psia
Electrical Termination:
PX409: Integral 2 m (6') cable
PX419: mini-DIN
PX429: Twist lock
PX459: M12 Connector
Mating Connectors:
PX419: CX5302 (included)
PX429: PT06F10-6S (sold separately)
Environmental Protection:
PX409: IP67
PX419: IP65
PX429: IP65
PX459: IP65
Wetted Parts: 316 SS
Pressure Port: ¼-18 NPT male
Weight: 115 to 200 g (4 to 7 oz) depending upon configuration
|
|
|
|
|
|
† Price are shown in RMB.
Note: Comes complete with 5 point calibration certificate.
To order models with different electrical terminations, change model number to on of the following:
PX409 = Cable Connection (featured in chart above)
PX419 = mini-DIN Connection (mating connector provided)
PX429 = Twist Lock Connector (mating connector sold separately)
Additional Ranges Available
See Part Number Builder (below) for hPa (mbar) pressure ranges.
Ordering Example: (1) PT06F10-6S Mating twist lock connector, ¥326.00, plus (1) PX429-26BI 4 to 20 mA output, 26 to 32 inHg absolute pressure, twist-lock termination, ¥9,125.00, ¥326.00 + 9,125.00 = $9,451.00
|
|
|
|
|
|
|
|
|
Part Number Builder |
|
|
|
|
|
|
Option Descriptions
|
(1)
|
Electrical Termination
|
|
Select PX409 for 2 m Cable PX419 for mini-DIN PX429 for Twist-lock (mating connector sold separately) PX459 for M12 Connector (mating connector/cable assembly sold separately)
(2)
|
hPa (mbar) Range Calibrations
|
|
Select 16B for 16 to 32 inHg 26B for 26 to 32 inHg 32B for 0 to 32 inHg 16HB for 550 to 1100 hPa 26HB for 880 to 1100 hPa 32HB for 0 to 1100 hPa
(3)
|
Electrical Output
|
|
Select V for 10mV/V 5V for 0-5 Volt Output 10V for 0-10 Volt Output I for 4-20 mA Output
(4)
|
Accuracy Options
|
|
Select for Standard 0.08% Accuracy -EH for 0.05% Accuracy -XL for 0.03% Linearity
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| | |
|
|
|
|
|
| |
Related Links -
Related Products
|
|
|
Related Products
|
|
PXM409:
|
High (0.08%) Accuracy Metric Pressure Transducers
|
|
|
|
|
PX02-BAR:
|
High Accuracy Electronic Barometer
|
|
|
|
|
DP41-B:
|
1/8 DIN Ultra High Performance Meter, Temperature, Thermocouple, RTD, Strain, Process - Discontinued
|
|
|
|
|
|
|
|
|
|