OMEGA’s PX101 Series voltage
output transducers feature a rugged
all stainless steel case and a highreliability
10 V amplified output.
They are designed for use in
critical applications in wastewater
management, chemical
manufacturing, water processing,
and industrial applications where
a non-plugging flush diaphragm is
needed.
SPECIFICATIONS Excitation: 16 to 30 Vdc Output: 0.5 to 10.5 Vdc Zero Balance: 0.5 V ±0.1 V Accuracy: ±0.5% linearity, hysteresis and repeatability combined Sensing Element: 4-active-arm bridge with hermetically sealed thick film strain gages Operating Temperature Range: -54 to 93°C (-65 to 200°F) Compensated Temperature Range: 16 to 71°C (60 to 160°F) Thermal Effects: Span: 0.01% rdg/°F Zero: 0.01% FS/°F Ranges (psi): 500, 1K, 2K, 3K, 5K, 6K; gage, sealed gage or absolute; metric ranges also available Proof Pressure:150% of rated capacity Burst Pressure: 300% of rated capacity Wetted Parts: 17-4 PH stainless steel Pressure Port: Flush diaphragm Electrical Connection: PTIH-8-4P (or equal) Optional: 3 m (10') 4-conductor shielded cable—specify model: PX101V0 (same price) Mating Connector: PT06F-8-4S (not included)
† Price are shown in RMB.
Note: See model PX61V for unamplified version. Metric Ranges Available – Consult Engineering Ordering Example: (1) PT06F8-4S Mating connector (sold separately), ¥291.00,
Part Number Builder
Option Descriptions
(1)
Electrical Termination
Select V0 for 10 foot cable V1 for PT1H-8-P connector (mating connector sold separately)
(2)
Pressure Range
Select 500 for 0-500 psi 1K for 0-1000 psi 2K for 0-2000 psi 3K for 0-3000 psi 5K for 0-5000 psi 6K for 0-6000 psi
(3)
Units
Select A10V for Absolute pressure G10V for Gage pressure